2016
DOI: 10.1016/j.ijpharm.2016.05.066
|View full text |Cite
|
Sign up to set email alerts
|

Real-time monitoring of the mechanism of ibuprofen-cationic dextran crystanule formation using crystallization process informatics system (CryPRINS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(20 citation statements)
references
References 32 publications
0
20
0
Order By: Relevance
“…Such methods would also be applicable to the synthesis process itself [37]. In this study, the probe-based (fiber)optical technologies Photon Density Wave (PDW) spectroscopy [3841], Focused Beam Reflectance Measurement (FBRM) [4245], Particle Vision Microscope (PVM) measurement [4648], and turbidity measurement [49–51] are applied to study the LCST of aqueous PNIPAM suspensions and additionally its heating and cooling rate dependency.…”
Section: Introductionmentioning
confidence: 99%
“…Such methods would also be applicable to the synthesis process itself [37]. In this study, the probe-based (fiber)optical technologies Photon Density Wave (PDW) spectroscopy [3841], Focused Beam Reflectance Measurement (FBRM) [4245], Particle Vision Microscope (PVM) measurement [4648], and turbidity measurement [49–51] are applied to study the LCST of aqueous PNIPAM suspensions and additionally its heating and cooling rate dependency.…”
Section: Introductionmentioning
confidence: 99%
“…As described in the specification, the RBI of PVM is positively correlated with the concentration and/or the size of the particulate matter in the liquid. The RBI is used to characterize the number of crystals when PVM is used for dynamic monitoring of the crystallization process (Abioye et al, ). However, it is clear that the concentration of solids in the present work has not changed, and the variation of RBI can only be attributed to the size of the suspended solids.…”
Section: Resultsmentioning
confidence: 99%
“…Particle vision and measurement (PVM) is a widely used instrument in the field of crystallization in recent years. By monitoring the dynamic process visually, researchers have obtained many important data and learned more about the crystallization process (Abioye, Chi, Simone, & Nagy, ; Szilagyi & Nagy, ). As a real‐time microscope, PVM continuously records images of particles and particle structures as they naturally exist in the process.…”
Section: Introductionmentioning
confidence: 99%
“…Based on various experiments, DEX-coated nanoparticles showed more colloidal stability behaviour compared to those of coated with PEG chains [65] and also they show no nonspecific protein binding activity [66]. Interestingly, due to the ability of substitution of plentiful hydroxyl groups at the surface of DEX with various functional groups, DEX can be easily modified and conjugated to various molecules such as fluorescent dye, tetramethylrhodamine (TRITC-dextran) [67] and different drugs including ibuprofen [68] and platinum(IV) [69]. The particle size and its distribution are two major factors that control vital properties of final dextran nanogels such as water absorption capacity and its kinetics.…”
Section: Cationic Dextranmentioning
confidence: 99%