Real-time quantification of hydrogen peroxide production in living cells using NiCo2S4@CoS2 heterostructure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 50 publications
(19 citation statements)
references
References 41 publications
0
19
0
Order By: Relevance
“…These results demonstrate that the NCT 1/GCE electrode can be used for the detection of H 2 O 2 and could be useful for physiological and pathological studies. 1 , 5 , 23 Scheme 2 describes H 2 O 2 release from RAW 267.4 living cells detected by the developed electrochemical sensor. This illuminates that the NCT 1/GCE NRs provide a promising platform to monitor H 2 O 2 .…”
Section: Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…These results demonstrate that the NCT 1/GCE electrode can be used for the detection of H 2 O 2 and could be useful for physiological and pathological studies. 1 , 5 , 23 Scheme 2 describes H 2 O 2 release from RAW 267.4 living cells detected by the developed electrochemical sensor. This illuminates that the NCT 1/GCE NRs provide a promising platform to monitor H 2 O 2 .…”
Section: Results and Discussionmentioning
confidence: 99%
“… 7 The NiCo 2 S 4 @CoS 2 electrode displayed the sensitivity of 1.49 μA μM –1 cm –2 , lower detection limit of 2 nM, and linear range of 12.64 nM to 2104 μM. 1 The CoNiSe/rGO nanocomposite shows a good electrocatalytic activity against glucose with the sensitivity of 18.89 mA mM –1 cm –2 , LOD of 0.65 μM, and linear range of 1 to 4000 μM. 8 …”
Section: Introductionmentioning
confidence: 99%
“…In addition to the advantages described above, Zhang et al [205] Several other research groups have employed the idea of combining more than one metal to fabricate electrochemical sensors for the detection of H2O2 in living cells [214,215]. For example, Mani et al [216] obtained an extraordinarily low LOD in the nanomolar range by modifying nickel cobalt sulfide/cobalt sulfide nanostructure arrays (NiCo2S4@CoS2 NAs) with a carbon cloth (CC). The NiCo2S4@CoS2 NAs provided a 3D hierarchical network with a highly porous structure and excellent conductive properties.…”
Section: Electrochemical Techniques For Hydrogen Peroxide (H 2 O 2 ) Detectionmentioning
confidence: 99%
“…Electrochemical sensors made with this material but not necessarily used to investigate living cells were reviewed elsewhere [85]. Three other TMDs (WS 2 [72], CoS 2 [80] and Mo 0.75 W 0.25 S 2 [83]) and an MXene (Ti 3 C 2 [81]) were also used to make electrochemical sensors to investigate living cells. It is difficult to say if one of these novel 2D materials is better for building electrochemical sensors than the other because the number of electrochemical sensors made with them is still too small and the devices are built in very different manners (e.g.…”
Section: Electrochemical Sensors Built With Non-graphene 2d Materialsmentioning
confidence: 99%