2019
DOI: 10.1016/j.yofte.2019.01.008
|View full text |Cite
|
Sign up to set email alerts
|

Refractive index sensor based on ultrafine tapered single-mode nocladding single-mode fiber structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(13 citation statements)
references
References 18 publications
0
13
0
Order By: Relevance
“…Optical fiber-based SPR sensors have been studied by researchers in recent years due to their advantages of easy miniaturization, remote sensing and in-situ monitoring [10]. In most fiber-based SPR sensors, the fiber is tapered or side polished and the exposed part is coated with a noble metal layer to produce SPR [11]. Gold and silver are the most common metals used in sensing layers.…”
Section: Introductionmentioning
confidence: 99%
“…Optical fiber-based SPR sensors have been studied by researchers in recent years due to their advantages of easy miniaturization, remote sensing and in-situ monitoring [10]. In most fiber-based SPR sensors, the fiber is tapered or side polished and the exposed part is coated with a noble metal layer to produce SPR [11]. Gold and silver are the most common metals used in sensing layers.…”
Section: Introductionmentioning
confidence: 99%
“…where α , λ , n ncf , and n medium are the radius of NCF, the free-space wavelength, the NCF RI, and the surrounding medium RI, respectively [ 37 ]. Thus, a change in V , which can be induced by the presence of mechanical deformation or surface RI fluctuation at the NCF region of the MMI apparatus, is now associated with the increased evanescent-wave portion of propagation modes due to coupling of multiple higher-order modes, which is responsible for sensitivity enhancement.…”
Section: Methodsmentioning
confidence: 99%
“…In 2018, Tian et al proposed a high sensitivity temperature sensor based on a tapered SNCS fiber structure and surrounded with alcohol within a silica capillary, where a maximum temperature sensitivity of 0.49 dB/°C has been achieved [207]. In 2019, Zhang et al proposed an RI sensors based on a tapered SNCS fiber structure (waist diameter 13 μm) with RI sensitivity of 686 nm/RIU within the RI range of 1.333-1.350 [208]. In 2020, Wang et al further proposed a folded-tapered SNCS fiber structure for simultaneous measurement of both RI (1191.5 nm/RIU) and temperature (0.0648 nm/°C) [209].…”
Section: A a Tapered Sms Fiber Structurementioning