Relationship between computerized wheeze detection and lung function parameters in young infants

Abstract: CORSA can help identify neonates and young infants with subclinical airway obstruction and may prove useful in the follow-up of high-risk infants.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
2

Year Published

2017
2017
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 37 publications
0
9
0
2
Order By: Relevance
“…In this case, pendelluft swinging to the site of including the short-term monitoring of treatment effects in bronchiolitis, 49 and in the comparison of wheeze detection and lung function in infants. 50 A multi-sensor array system for "vibration response imaging"…”
Section: Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…In this case, pendelluft swinging to the site of including the short-term monitoring of treatment effects in bronchiolitis, 49 and in the comparison of wheeze detection and lung function in infants. 50 A multi-sensor array system for "vibration response imaging"…”
Section: Measurementmentioning
confidence: 99%
“…In 2008, Pulmotrack (KarmelSonix, Haifa, Israel) was the first stand‐alone wheeze monitor to receive approval by the US Food and Drug Administration (FDA). It has been applied in several pediatric studies, including the short‐term monitoring of treatment effects in bronchiolitis, and in the comparison of wheeze detection and lung function in infants . A multi‐sensor array system for “vibration response imaging” (VRIxp, Deep Breeze, Or‐Akiva, Israel), that is, for the spatial mapping of chest sounds, was FDA approved in 2008 and has been used in a study of wheezes .…”
Section: Introductionmentioning
confidence: 99%
“…In our sound spectrogram (time vs sound frequency), typical wheezing can be observed as a bright wave-type band from left to right, mainly in the high-pitched area of the expiratory phase. 34,35 After the assessment of the response to a methacholine inhalation challenge with an Astograph (Chest Co.), wheezing is not usually heard by auscultation, and a fine difference in the sound intensity and/or tone may be recognized by careful physicians.…”
Section: Discussionmentioning
confidence: 99%
“…El uso de esta tecnología ha permitido una interpretación más objetiva de los ruidos respiratorios, pero también ha tenido oportunidades de tener un rol en la toma de decisiones clínicas respecto a la terapia de pacientes con enfermedades respiratorias. Varios estudios han mostrado que CORSA ha sido útil en pacientes con asma en la detección de sibilancias durante las pruebas de provocación bronquial, contando con una fuerte correlación con el grado de obstrucción bronquial que presenta el paciente 39,40 . En un estudio realizado en 22 lactantes con bronquiolitis aguda se pudo establecer la respuesta clínica al uso de salbutamol en relación al tipo de sibilancias que presentaba en el análisis acústico realizado 41 .…”
Section: Nuevos Avances En Auscultación Pulmonarunclassified