Relative quantification of polyethylene glycol 400 excreted in the urine of male and female volunteers by direct injection electrospray-selected ion monitoring mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
12
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 24 publications
1
12
0
Order By: Relevance
“…Following infusion into the Q-TOF MS from a syringe pump, PEG standard solutions were full scanned in the TOF-MS mode with CE set at the minimum value and DP adjusted manually. For low MW PEGs, a normal distribution of singly charged PEG precursor ions was observed (Figure A) with [M + H] + , [M + Na] + , and [M + K] + ions all present in good agreement with a previous report . For medium and high MW PEGs (Figure B and C), irrespective of how DP was adjusted, only ions with m / z in the range 400–1400 were observed and virtually no ions with m / z > 2500.…”
Section: Resultssupporting
confidence: 89%
See 1 more Smart Citation
“…Following infusion into the Q-TOF MS from a syringe pump, PEG standard solutions were full scanned in the TOF-MS mode with CE set at the minimum value and DP adjusted manually. For low MW PEGs, a normal distribution of singly charged PEG precursor ions was observed (Figure A) with [M + H] + , [M + Na] + , and [M + K] + ions all present in good agreement with a previous report . For medium and high MW PEGs (Figure B and C), irrespective of how DP was adjusted, only ions with m / z in the range 400–1400 were observed and virtually no ions with m / z > 2500.…”
Section: Resultssupporting
confidence: 89%
“…In recent years, the rapidly developing technique of LC-MS/MS has raised bioanalysis to a new level. Its first application to PEGs was to measure PEG 400 in urine based on direct injection electrospray ionization (ESI) combined with detection by selected ion monitoring (SIM) . Unfortunately the technique was of limited selectivity and prone to interference from endogenous substances.…”
mentioning
confidence: 99%
“…This is generally the case [23 ,24] when deuterium is used as stable isotope label. In our method half of the labels (4 and 8 labels respectively) were deuterium, but with the high MW of PEG ( below the data found in literature, which ranged from 0.1 to 50 µg/mL for PEG 400 with ELSD and RI detection [3,5,7] and 45 to 800 ng/mL for PEG 300 and PEG 400 with MS detection, respectively [8][9][10]. Data for the larger PEG varied between 0.1 and 5 µg/mL with ELSD and RI [3][4][5]7], but no values for MS detection of PEG with similar MW could be found.…”
Section: Discussionmentioning
confidence: 64%
“…Examples for overlaps are (1) the ammonium adduct of PEG13 (m/z 608.7 Da) and PEG80 with six ammonium charges (m/z 608.4 Da) or (2) PEG65 with five ammonium charges (m/z 594.3 Da), six fold ammoniated PEG78 (m/z 593.7 Da) and the adduct of PEG91 with seven ammonium (m/z 593.3 Da). This restriction could be circumvented by LC separation, but this clearly extended the measurement time in comparison to other methods [8][9][10][11]. In the chromatograms a shift of retention time between the analyte and the corresponding labelled standard of about 0.1 min was observed.…”
Section: Discussionmentioning
confidence: 99%