2005
DOI: 10.1109/tns.2005.852709
|View full text |Cite
|
Sign up to set email alerts
|

Response of RadFET dosimeters to high fluences of fast neutrons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…For doses exceeding 10 Gy their response curve becomes strongly sub-linear, i.e., begins to saturate. Although the responses of all MOSFETs under "zero bias" are always strongly sub-linear [10], the REM devices at the same total dose are not saturating in this way. The saturation mechanism is not well understood but it is clear that further electron escape might be retarded by built-in oxide fields due to oxide-trapped positive charge [31].…”
Section: Discussion Of the Ratio "Rem Response/laas Response" Or "mentioning
confidence: 95%
See 2 more Smart Citations
“…For doses exceeding 10 Gy their response curve becomes strongly sub-linear, i.e., begins to saturate. Although the responses of all MOSFETs under "zero bias" are always strongly sub-linear [10], the REM devices at the same total dose are not saturating in this way. The saturation mechanism is not well understood but it is clear that further electron escape might be retarded by built-in oxide fields due to oxide-trapped positive charge [31].…”
Section: Discussion Of the Ratio "Rem Response/laas Response" Or "mentioning
confidence: 95%
“…It has been shown [10], [32] that the distribution and composition of the materials around RadFETs can strongly interfere with TID measurements, especially in radiation fields containing neutrons and/or low energy photons. Dose enhancement effects are thus an issue.…”
Section: Sensor Carrier For the Lhc Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Only few experimental works have been reported on this topic. For example, the increase of the dose measured with RadFETs exposed to fast neutrons and covered with Polyethylene slabs of different thicknesses was investigated in [10]. RadFETs exposed to a Co-60 source and to monoenergetic low energy protons, covered or not covered by a lid were investigated in [11].…”
Section: Authorsmentioning
confidence: 99%
“…At intermediate energies (8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25) GeV) the Parameterized models, originally derived from GHEISHA [37], were activated. The highest energy range (20 GeV-100 TeV) was covered by the Quark Gluon String model [39].…”
Section: Geant4 Applicationmentioning
confidence: 99%