Results of silicon pore optics mirror modules optical integration in the ATHENA telescope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Recently at PANTER tests were done to check two competing Assembly Integration and Testing (AIT) methods to mount and co-align the SPO modules into the mirror assembly in this case two optics into a mini petal. One AIT approach (Media Lario) [15,16] uses UV light to check the alignment of the optics into the petal. The other approach (Thales-CH) [17,18] used a metrology characterization of the individual optics at BESSY and then co-aligned them based on the metrology in PANTER.…”
Section: Recent Athena and Arcus Related Testsmentioning
confidence: 99%
“…Recently at PANTER tests were done to check two competing Assembly Integration and Testing (AIT) methods to mount and co-align the SPO modules into the mirror assembly in this case two optics into a mini petal. One AIT approach (Media Lario) [15,16] uses UV light to check the alignment of the optics into the petal. The other approach (Thales-CH) [17,18] used a metrology characterization of the individual optics at BESSY and then co-aligned them based on the metrology in PANTER.…”
Section: Recent Athena and Arcus Related Testsmentioning
confidence: 99%
“…Figure 9 shows the UV and X-ray images of the resulting PSF, with clearly visible overlapped centroids. Figure 10 shows the X-ray x-FWHM and the centroid distance, all plotted against the focal distance [13].…”
Section: Integration Demonstrator and Resultsmentioning
confidence: 99%
“…Each SPO MM can be removed and replaced if found to be misaligned. This process has already been tested, and found to meet the Arcus requirement of increasing the PSF in the dispersion direction by less than 1.5 arcsec HEW [27].…”
Section: Optical Alignmentmentioning
confidence: 99%
“…The SPO MMs will be aligned into the SPO petal using the same procedure as developed and tested for Athena [27]. Fine alignment is performed under illumination by a planar UV wavefront.…”
Section: Optical Alignmentmentioning
confidence: 99%