2014
DOI: 10.1109/tpel.2013.2294919
|View full text |Cite
|
Sign up to set email alerts
|

Robust Predictive Control of Grid-Tied Converters Based on Direct Power Control

Abstract: This work focuses on the control of instantaneous complex power of a grid-connected VSI. In this work, a new space vector modulation based direct power control approach is proposed: the Robust Predictive Direct Power Control (RP-DPC). The proposed predictive control algorithm ensures that both, instantaneous real and imaginary powers track the reference with high speed and accuracy reducing steady-state errors. In order to reduce the Total Harmonic Distortion (THD) in the output currents, a Fundamental Frequen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
39
0
2

Year Published

2016
2016
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 72 publications
(41 citation statements)
references
References 26 publications
0
39
0
2
Order By: Relevance
“…Diferentes controladores han sido desarrollados a partir del concepto original para mejorar la respuesta del inversor en sistemas con conexión a red. En [12], el control predictivo es mejorado utilizando estimación pa-ramétrica, mientras que en [13] se desarrolla un control predictivo robusto de corriente. Por su parte, en [14] se diseña un filtro para disminuir la distorsión armónica de la corriente inyectada en el punto de conexión.…”
Section: Introductionunclassified
“…Diferentes controladores han sido desarrollados a partir del concepto original para mejorar la respuesta del inversor en sistemas con conexión a red. En [12], el control predictivo es mejorado utilizando estimación pa-ramétrica, mientras que en [13] se desarrolla un control predictivo robusto de corriente. Por su parte, en [14] se diseña un filtro para disminuir la distorsión armónica de la corriente inyectada en el punto de conexión.…”
Section: Introductionunclassified
“…For this reason, the harmonic restriction standards such as IEEE-519 or IEC 61000-3-2 have been published to limit the amount of harmonic current injected into utility grid [12]. In the same vein, many researchers have investigated the strategies to improve the power quality of the grid connected inverter by mitigating the current harmonics [11][12][13][14][15][16][17][18]. As a selective harmonic compensation scheme, a proportional integral (PI)-resonant current controller has been presented to compensate low-order harmonic terms selectively [13,16].…”
Section: Introductionmentioning
confidence: 99%
“…As a selective harmonic compensation scheme, a proportional integral (PI)-resonant current controller has been presented to compensate low-order harmonic terms selectively [13,16]. As an alternative method, nonselective harmonic compensation techniques such as the sliding mode control [11], predictive control [17], and repetitive control [18] have been designed.…”
Section: Introductionmentioning
confidence: 99%
“…Other approaches to eliminate the harmonics from inverter current use nonlinear control techniques such as the sliding mode control (SMC) [12], predictive control [13], or repetitive control [14]. These control strategies are often referred as non-selective method since the controllers work in wide range of frequency, in contrast to the selective method that only regulates the harmonics in some specified orders.…”
Section: Introductionmentioning
confidence: 99%