2014
DOI: 10.1016/j.prosdent.2013.07.024
|View full text |Cite
|
Sign up to set email alerts
|

Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
36
0
22

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 52 publications
(61 citation statements)
references
References 20 publications
3
36
0
22
Order By: Relevance
“…The current study showed the maintained torque was lower than the tightening torque for the screws in all groups, which is in agreement with previous studies 3,5,[6][7][8] . This likely occurs due to the phenomenon known as "settling" or "embedment relaxation" 3 .…”
Section: Discussionsupporting
confidence: 93%
See 2 more Smart Citations
“…The current study showed the maintained torque was lower than the tightening torque for the screws in all groups, which is in agreement with previous studies 3,5,[6][7][8] . This likely occurs due to the phenomenon known as "settling" or "embedment relaxation" 3 .…”
Section: Discussionsupporting
confidence: 93%
“…The higher torque maintenance found for the two holding techniques may be because a longer torque application decreases the irregularities in the threads of the implant and retaining screw, increasing the contact between them during the preload and consequently, decreasing the settling effect. The retorque application after the settling effect may act to regain preload and increase the contact area between the threads; for this reason, several researchers have advocated that retorque application 10 min after the initial application should be performed routinely during abutment-implant connections 3,5,6 . The current study showed that this technique was most effective when associated with holding the torque for 20 s.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[12][13][14] Secondary torque application has also been found to increase joint stability, even when a purposeful misfit between items is present. 15 Handheld screwdrivers have been shown to produce inconsistent torque values on implant screws and abutments. 16 Not all abutment screw types can be successfully tightened by hand.…”
Section: Discussionmentioning
confidence: 99%
“…Retighten the screw after 10 minutes to the definitive torque level. 17 Close the screw access opening with Teflon tape. 3.…”
Section: Techniquementioning