2016
DOI: 10.4236/ojce.2016.64055
|View full text |Cite
|
Sign up to set email alerts
|

Seismic Evaluation of Reinforced Concrete Frames in the Harsh Environment Using Pushover Analysis

Abstract: The main objective of this paper is to evaluate the seismic response of buildings of typical reinforced concrete frames when concrete starts to deteriorate gradually and to make a comparison between the base shear and the displacement at different stages of earthquake loading. Typical 5, 15, 20 and 30-storey reinforced concrete frames have been designed for seismicity according to the recently adopted seismic code in Abu Dhabi, ACI 318-08/IBC 2009 code. A pushover analysis has been performed to these four buil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2016
2016
2016
2016

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…For 15-storey building, it was noticed that the base shear decreases when the concrete strength decreases and the displacement at point "D" is increasing whenever the concrete strength is decreasing for all different cases, i.e.,4000 psi, 3500 psi, 3000 psi, 2500 psi, 2000 psi and 1500 psi. Also it was noticed that the failure occurred at the 4th and 5th floors for all cases except for 1500 psi the failure was at the 3rd, 4th and 5th floors, more details can be found in reference [6].…”
Section: Discussion Of Resultsmentioning
confidence: 95%
See 3 more Smart Citations
“…For 15-storey building, it was noticed that the base shear decreases when the concrete strength decreases and the displacement at point "D" is increasing whenever the concrete strength is decreasing for all different cases, i.e.,4000 psi, 3500 psi, 3000 psi, 2500 psi, 2000 psi and 1500 psi. Also it was noticed that the failure occurred at the 4th and 5th floors for all cases except for 1500 psi the failure was at the 3rd, 4th and 5th floors, more details can be found in reference [6].…”
Section: Discussion Of Resultsmentioning
confidence: 95%
“…For the 5-storey building, model it was noticed that the plastic hinges start to occur in the beams in earlier steps and none of the plastic hinges occur in the columns. But in the 15, 20 and 30-storey buildings plastic hinges start to occur in the beams in earlier steps and at the columns in later steps, which satisfied the weak beam-strong column criteria, more details can be found in reference [6].…”
Section: Discussion Of Resultsmentioning
confidence: 98%
See 2 more Smart Citations