2014
DOI: 10.1002/ceat.201400234
|View full text |Cite
|
Sign up to set email alerts
|

Selection of Biphasic Liquid Systems in Liquid‐Liquid Chromatography Using Predictive Thermodynamic Models

Abstract: The possibility of using thermodynamic models for screening biphasic liquid systems, including systems for which liquid‐liquid equilibrium data are not available, is demonstrated. The liquid‐liquid equilibrium in different biphasic systems and the partition coefficients of solutes in these systems are predicted with UNIFAC and COSMO‐RS. The predictions are based only on the molecular structure of the solutes and solvents. The advantages and limitations of the two models are explored using fourteen solutes and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
20
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(21 citation statements)
references
References 39 publications
1
20
0
Order By: Relevance
“…That means that 173 mL correspond to stationary phase and 38 mL to mobile phase. Therefore, both compounds are highly diluted after a pulse injection, which allows us to state that the calculated KD´s are closer to the real values [ 41 , 42 ]. After several CPC runs, the HPLC analysis of the core cuts from the center of the peaks allow to confirm the presence of verbascoside and forsythoside B in high purity ( Figure 5 B).…”
Section: Resultsmentioning
confidence: 99%
“…That means that 173 mL correspond to stationary phase and 38 mL to mobile phase. Therefore, both compounds are highly diluted after a pulse injection, which allows us to state that the calculated KD´s are closer to the real values [ 41 , 42 ]. After several CPC runs, the HPLC analysis of the core cuts from the center of the peaks allow to confirm the presence of verbascoside and forsythoside B in high purity ( Figure 5 B).…”
Section: Resultsmentioning
confidence: 99%
“…In this work, the software COSMOconfX (Version 4.0, COSMOlogic, Leverkusen, Germany) and COSMOthermX (Version: C30 Release 16.01., COSMOlogic, Leverkusen, Germany) was used. The approach used for the screening and selection of biphasic solvent systems for CCC/CPC separations is described in detail in the literature [21][22][23].…”
Section: Biphasic Solvent System Screening With Predictive Thermodynamic Modelmentioning
confidence: 99%
“…The main advantages of COSMO‐RS were its independence of experimental data and capable of distinguish spatial isomers [49–51]. Literature comparing the capabilities for predicting between COSMO‐RS and UNIFAC showed that UNIFAC was more accurate for predicting liquid‐liquid equilibrium data, while COSMO‐RS was superior to more complicated compounds such as isomers and natural products [52] (Table 1).…”
Section: Prediction Of Partition Coefficientmentioning
confidence: 99%