“…The value obtained for C20:1n9 (ECL = 20.62) (here, using a temperature gradient) corresponds well with the data reported by Ando and Sasaki (ECL = 20.57-20.73, depending on isothermal temperature) [35]. Recently, an even more polar IL phase (SLB-IL 111) was also evaluated for FAME analysis [36]. On this column, the unsaturated fatty acids are even more retained and saturated fatty acids (C x :0) interfere with mono-unsaturated fatty acids with one carbon less (C x−1 :1).…”
Section: Gc-ms Analysis Using Ionic Liquid Stationary Phasessupporting
confidence: 68%
“…Polar ionic liquid phases were used for the analysis of fatty acid methyl esters [32][33][34], and their potential for the separation of eicosenoic acid (C20:1) isomers [35] and octadecenoic acid (C18:1) and octadecadienoic acid (C18:2) isomers [36] was demonstrated. For these applications, flame ionization detection (FID) was used.…”
“…The value obtained for C20:1n9 (ECL = 20.62) (here, using a temperature gradient) corresponds well with the data reported by Ando and Sasaki (ECL = 20.57-20.73, depending on isothermal temperature) [35]. Recently, an even more polar IL phase (SLB-IL 111) was also evaluated for FAME analysis [36]. On this column, the unsaturated fatty acids are even more retained and saturated fatty acids (C x :0) interfere with mono-unsaturated fatty acids with one carbon less (C x−1 :1).…”
Section: Gc-ms Analysis Using Ionic Liquid Stationary Phasessupporting
confidence: 68%
“…Polar ionic liquid phases were used for the analysis of fatty acid methyl esters [32][33][34], and their potential for the separation of eicosenoic acid (C20:1) isomers [35] and octadecenoic acid (C18:1) and octadecadienoic acid (C18:2) isomers [36] was demonstrated. For these applications, flame ionization detection (FID) was used.…”
“…2 and 12 and Nakamura et al 14 for the same GC column and Ando and Sasaki 15 for the SLB-IL100 GC column. The IS c14-20:1 eluted Fig.…”
Section: Percentage Of Lipid Contentmentioning
confidence: 99%
“…The SLB-IL111 GC capillary column has the stationary phase with the highest polarity that has been commercialized for use in capillary GC 12 .…”
Section: Percentage Of Lipid Contentmentioning
confidence: 99%
“…Nevertheless, the identification of LC-MUFA positional isomers from a complex mixture of fatty acid methyl esters FAME presents a major challenge due to overlap with other FAs. It has been previously reported that the geometric isomers of α-linolenic acid, γ-linolenic acid, and heneicosanoic acid 21:0 overlap with the isomers of c-20:1 on the SLB-IL111 GC column 12 .…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.