2016 IEEE World Conference on Factory Communication Systems (WFCS) 2016
DOI: 10.1109/wfcs.2016.7496500
|View full text |Cite
|
Sign up to set email alerts
|

Simulation models for IEC 61850 communication in electrical substations using GOOSE and SMV time-critical messages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
4
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(6 citation statements)
references
References 13 publications
0
5
0
1
Order By: Relevance
“…IEC 61850 adalah standar komunikasi untuk Sistem Otomasi Gardu Induk (SOGI). IEC 61850 ini mendefinisikan model informasi dan layanan yang digunakan untuk komunikasi antara Intelligent Electronic Device (IED) di gardu induk [3]. IEC 61850 merupakan keluarga standar komunikasi yang menetapkan protokol penamaan perangkat, data dan jaringan komunikasi yang terkait dengan otomatisasi gardu tenaga listrik.…”
Section: Pendahuluanunclassified
“…IEC 61850 adalah standar komunikasi untuk Sistem Otomasi Gardu Induk (SOGI). IEC 61850 ini mendefinisikan model informasi dan layanan yang digunakan untuk komunikasi antara Intelligent Electronic Device (IED) di gardu induk [3]. IEC 61850 merupakan keluarga standar komunikasi yang menetapkan protokol penamaan perangkat, data dan jaringan komunikasi yang terkait dengan otomatisasi gardu tenaga listrik.…”
Section: Pendahuluanunclassified
“…We developed in a previous work [13] a tool to automatically generate a network architecture from IEC 61850 network configuration files. This work is based on the one made by Léon et al [14], where an IEC 61850 model was proposed. Even though we can run simulations with scenarios that make it easier to get the worst case delay, the latter may actually never be reached since the worstcase is rare event during simulations.…”
Section: A Related Workmentioning
confidence: 99%
“…The same scenario presented in Figure 4 was assessed using a set of simulation models developed for the OMNeT++ and INET frameworks, previously presented in [33] and available in [34]. In addition to the simulation models originally available in OMNeT++, a set of specific models were developed for the simulation of elements of an SAS control bus.…”
Section: Simulation Assessmentmentioning
confidence: 99%
“…The following abbreviations are used in this manuscript: In this appendix, we present the conformance statements of the proposed simulator that provide the required elements to assess IEC 61850 process bus deployments. A preliminary description of this simulator tool was presented in [33], and additional information about the simulator library and its corresponding source-code is available at [34].…”
Section: Conflicts Of Interestmentioning
confidence: 99%