2011
DOI: 10.1016/j.jchromb.2011.05.028
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous analysis of chlorpyrifos and cypermethrin in cord blood plasma by online solid-phase extraction coupled with liquid chromatography–heated electrospray ionization tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(16 citation statements)
references
References 22 publications
0
16
0
Order By: Relevance
“…The levels of pyrethroids and their residues in the blood of people exposed to pyrethroids are either very low (1 ppb) or undetectable (Ramesh and Ravi, 2004;Liao et al, 2011). The levels of pyrethroids and their residues in urine are usually higher (up to 1 mM) despite undetectable levels in the blood of the same people (Leng et al, 1997).…”
Section: Discussionmentioning
confidence: 99%
“…The levels of pyrethroids and their residues in the blood of people exposed to pyrethroids are either very low (1 ppb) or undetectable (Ramesh and Ravi, 2004;Liao et al, 2011). The levels of pyrethroids and their residues in urine are usually higher (up to 1 mM) despite undetectable levels in the blood of the same people (Leng et al, 1997).…”
Section: Discussionmentioning
confidence: 99%
“…As an alternative, LC-HRMS offers the possibility of detecting hundreds of polar contaminants in a quantitative target approach due to its sensitivity and selectivity in full-scan analysis. Furthermore, it allows the detection of known compounds suspected of being present in environmental samples (suspect screening) without reference standards, even after measurement (post-target screening) and the screening of yet unknown non-target chemicals [87][88]. The use of HRMS, such as TOF or Orbitrap, for multiresidue analysis is largely driven by the advantages of using the full-scan acquisition mode with high sensitivity, combined with high-resolving power (> 50000 FWHM) and accurate mass measurement (1-5 ppm) [89].…”
Section: Instrumental Techniquesmentioning
confidence: 99%
“…The pesticides and their product ions were confirmed via comparison of their mass spectra with those from an analytical protocol provided by the Taiwan Food and Drug Administration (TFDA) and other relevant references. [21][22][23][24][25] The experimental results indicate that point-of-care application of TD-ESI-MS for simultaneous identification of multiple pesticide compounds is achievable.…”
Section: Ms/ms Analysis (Data Not Shown) the Results Of The Ms And Mmentioning
confidence: 93%