2000
DOI: 10.1016/s0378-4347(00)00392-3
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous chiral analysis of methamphetamine and related compounds by capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
40
0

Year Published

2001
2001
2018
2018

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 59 publications
(40 citation statements)
references
References 10 publications
0
40
0
Order By: Relevance
“…3. Migration order and identification of each peak in electropherograms were obtained by spiking a single isomer and comparing with previous work [33,39]. EP enantiomers were found to have reversed migration order for b-CD and DM-b-CD, while the same migration orders were obtained for other enantiomers.…”
Section: Observed and Predicted˜ì And Ae Of Test Enantiomers In Dual Cdsmentioning
confidence: 77%
See 2 more Smart Citations
“…3. Migration order and identification of each peak in electropherograms were obtained by spiking a single isomer and comparing with previous work [33,39]. EP enantiomers were found to have reversed migration order for b-CD and DM-b-CD, while the same migration orders were obtained for other enantiomers.…”
Section: Observed and Predicted˜ì And Ae Of Test Enantiomers In Dual Cdsmentioning
confidence: 77%
“…One approach to enhance the simultaneous separation of all analytes is the use of dual CDs, a combination of two CD types, in the BGE. The following dual neutral CDs have been shown to improve simultaneous separation of several pairs of enantiomers: b-and g-CDs for Dns-DL-amino acids [29], a-and trimethyl-b-cyclodextrins (TM-b-CDs) for binaphthyl compounds [30], b-and TM-b-CDs or g-and TM-b-CDs for phenoxy acid herbicides [31], b-and g-CDs for polychlorinated biphenyls [32], and b-and DM-b-CDs for amphetamine (AP) drugs [33]. In comparison with a single charged CD, dual chiral selectors as neutral and charged CDs have been reported to provide benefit of better resolution and peak shape [34].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The same compounds were previously analyzed by Chinaka et al by CE/diode-array detection (DAD) using 75 mM tris(hydroxymethyl)-aminomethane (Tris) buffer as a background electrolyte, and the same CDs as a chiral selector. 4 The resolutions of these compounds are also shown in the right part of Table 1. Using Tris, neutral CDs and a DAD detector, the chiral resolutions of all compounds, except AP, were over 1, but, using formic acid, neutral CDs and the MS detector, the chiral resolutions of all compounds, except NE, were under 1.…”
Section: Choice Of Anionic Cds and Comparison With Neutral Cdsmentioning
confidence: 99%
“…8) The electrolyte was Tris buffer (pH 2.5) containing β-CD and heptakis(2,6-di-O-methyl)-β-CD (DM-β-CD). This method successfully separated all 18 enantiomers simultaneously (Fig.…”
Section: Drug Samplesmentioning
confidence: 99%