2005
DOI: 10.1016/j.jchromb.2005.03.033
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of histamine and polyamines by capillary zone electrophoresis with 4-fluor-7-nitro-2,1,3-benzoxadiazole derivatization and fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
15
0

Year Published

2006
2006
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(16 citation statements)
references
References 53 publications
1
15
0
Order By: Relevance
“…Alternatively, Krausova et al [27,28] extended the application of a MEKC with UV detection to the analysis of biogenic amines in numerous meat matrices, including young bull, cow, pig and chicken livers. A new procedure based on the use of CZE with lamp-induced fluorescence detection and 4-fluor-7-nitro-2,1,3-benzoxadiazole as derivatization reagent was developed to determine histamine and polyamines including spermine, spermidine, diaminopropane, putrescine, cadaverine and diaminohexane [29]. A detection limit for the amines (10 nM) comparable to other CE analytical methods without using laser as the excitation radiation was achieved.…”
Section: Amino Acids Biogenic Amines and Nitrosaminesmentioning
confidence: 99%
“…Alternatively, Krausova et al [27,28] extended the application of a MEKC with UV detection to the analysis of biogenic amines in numerous meat matrices, including young bull, cow, pig and chicken livers. A new procedure based on the use of CZE with lamp-induced fluorescence detection and 4-fluor-7-nitro-2,1,3-benzoxadiazole as derivatization reagent was developed to determine histamine and polyamines including spermine, spermidine, diaminopropane, putrescine, cadaverine and diaminohexane [29]. A detection limit for the amines (10 nM) comparable to other CE analytical methods without using laser as the excitation radiation was achieved.…”
Section: Amino Acids Biogenic Amines and Nitrosaminesmentioning
confidence: 99%
“…In addition, reproducibility of CE is usually not as great as the other two techniques, mainly due to variation of EOF as a result of adsorption of solutes on the capillary wall. Because most biogenic amines are protonated (R-NH 3 1 under physiological conditions, they are cations and thus their separations by CZE are commonly carried out under acidic conditions in the presence of small EOF [17,18]. However, the separations of biogenic amines by CZE are sometimes unsuccessful, especially because the biogenic amines have low hydrophilic properties, similar dissociation constant (K a ) values, and the tendency to be adsorbed on the capillary wall.…”
Section: Introductionmentioning
confidence: 99%
“…After being thoroughly mixed, derivatization reaction was conducted at 601C for 1 min in a water bath under dark. Then, the mixture was diluted with the running buffer solution to quench the labeling reaction; of course, it was also directly applied to injection for CE without dilution [22]. Reagent blanks without the target analytes were treated in the same way.…”
Section: Nbd-f-labeled Epmentioning
confidence: 99%