2000
DOI: 10.1016/s0021-9673(99)01257-1
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous stereoselective analysis of tramadol and its main phase I metabolites by on-line capillary zone electrophoresis–electrospray ionization mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
53
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 80 publications
(53 citation statements)
references
References 52 publications
0
53
0
Order By: Relevance
“…Thus, two different derivatization protocols for amino acids using dansyl chloride (DNS) and FITC were compared observing better mass sensitivity for FITC-amino acids (LODs in the mM range) [139]. CE-ESI-MS has also been used for the sensitive determination of chiral compounds in biological samples such as urine [135,140,141], plasma [142], serum [143], and in vivo samples [144], and for the identification of drugs and their metabolites [145,140].…”
Section: Alternative Detection Systems To On-column Uv-vis Absorptionmentioning
confidence: 99%
“…Thus, two different derivatization protocols for amino acids using dansyl chloride (DNS) and FITC were compared observing better mass sensitivity for FITC-amino acids (LODs in the mM range) [139]. CE-ESI-MS has also been used for the sensitive determination of chiral compounds in biological samples such as urine [135,140,141], plasma [142], serum [143], and in vivo samples [144], and for the identification of drugs and their metabolites [145,140].…”
Section: Alternative Detection Systems To On-column Uv-vis Absorptionmentioning
confidence: 99%
“…Tramadol (TMD) is a centrally acting drug that possesses an analgesic action. TMD is formulated as a racemic mixture, where each enantiomer displays different binding properties for various receptors [16][17][18]. Methadone (MTD) is a synthetic opiate largely used as an analgesic drug [19].…”
Section: Introductionmentioning
confidence: 99%
“…21 Although both of the aforementioned techniques avoid the detrimental effects of chiral selector on the MS signal, the former is somewhat limited to the chiral analysis of charged compounds while the latter provides lower resolution and lower peak capacity compared to the standard MEKC-MS. 22 These aforementioned disadvantages have prompted the combined use of counter-migration and PF which demonstrated higher CE resolution and higher MS sensitivity. 23 In the past ten years, polymeric surfactants 24-26 (aka. molecular micelle) has been widely employed as pseudostationary phases for chiral 27-35 and achiral 36-38 separations in MEKC.…”
mentioning
confidence: 99%