2017
DOI: 10.1016/j.psep.2017.08.025
|View full text |Cite
|
Sign up to set email alerts
|

Single and mixture adsorption of clofibric acid, tetracycline and paracetamol onto Activated carbon developed from cotton cloth residue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
26
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 87 publications
(28 citation statements)
references
References 50 publications
1
26
0
1
Order By: Relevance
“…Therefore, to eliminate the insignicant terms from the second-order polynomial model, model reduction was conducted for both the yield and iodine adsorption values. The nal equation in terms of coded factors were obtained as follows as eqn (9) and 10:…”
Section: Optimizationmentioning
confidence: 99%
“…Therefore, to eliminate the insignicant terms from the second-order polynomial model, model reduction was conducted for both the yield and iodine adsorption values. The nal equation in terms of coded factors were obtained as follows as eqn (9) and 10:…”
Section: Optimizationmentioning
confidence: 99%
“…The suitability of the Langmuir isotherm to fit the data was confirmed by the exponent value of the Redlich-Peterson model, n, which was near to one. It should be noted that most of the isotherm adsorption studies of pharmaceutical products on various adsorbents follow the Langmuir isotherm model [26][27][28][29][30][31][32][33][34][35]. The monolayer adsorption capacity, qm, was found to be 4.21 mg g -1 .…”
Section: Resultsmentioning
confidence: 99%
“…DO probe, (10) air flow meter, (11) air compressor, (12) sedimentation tank, (13) sludge, (14) effluent, (15) clapboard Source: Adapted from Ru-Jin et al [36] of a multiparameter bench photometer (HI 83200, Hanna Instruments Inc., America). Ammonium molybdate spectrophotometric method was used to calculate the concentration of TP [23,27,41]. DO probe (JPB-607, Shanghai Jingsheng Scientific instrument Co. Ltd., China) was used to measure the level of DO with an online real time determination.…”
Section: Methodsmentioning
confidence: 99%
“…The modern studies that emphasize the extensive utilization of waste cotton cloth concentrate on the extraction of some chemical compounds, such as cellulose nanocrystals [17] and extraction of nanocellulose through a novel one-pot isolation system [26]. Furthermore, a study on production of single and mixture adsorption was conducted by Boudrahem et al [27] and bacterial cellulose production by Feng et al [8]. Also, waste cotton cloth has been used for tensile and fatigue characterization in the area of polypropylene matrix for composites applications such as the industries dealing with automotive [28].…”
Section: Introductionmentioning
confidence: 99%