2015
DOI: 10.1063/1.4909544
|View full text |Cite
|
Sign up to set email alerts
|

Spin echo small angle neutron scattering using a continuously pumped 3He neutron polarisation analyser

Abstract: We present a new instrument for spin echo small angle neutron scattering (SESANS) developed at the Low Energy Neutron Source (LENS) at Indiana University. A description of the various instrument components is given along with the performance of these components. At the heart of the instrument are a series of resistive coils to encode the neutron trajectory into the neutron polarisation. These are shown to work well over a broad wavelength range of neutron wavelengths. Neutron polarisation analysis is accomplis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 52 publications
0
19
0
Order By: Relevance
“…For each SESANS measurement, we plot the 'normalised SESANS signal'. 70,71 Qualitatively this can be interpreted as a correlation function G(z) related to a Debye type correlation function. At long spin-echo lengths G(z / N) the value of this normalised spin-echo signal is given by S t and this can be converted directly to a volume fraction when scattering is observed.…”
Section: Resultsmentioning
confidence: 99%
“…For each SESANS measurement, we plot the 'normalised SESANS signal'. 70,71 Qualitatively this can be interpreted as a correlation function G(z) related to a Debye type correlation function. At long spin-echo lengths G(z / N) the value of this normalised spin-echo signal is given by S t and this can be converted directly to a volume fraction when scattering is observed.…”
Section: Resultsmentioning
confidence: 99%
“…An in-situ NSF has been operated routinely on the Magnetism Reflectometer at the SNS 21 (Tong et al , 2012) and smaller in-situ systems have been developed for the HB3 triple-axis spectrometer and the hybrid spectrometer (HYSPEC) at the SNS (Jiang et al , 2014). At LENS 22 , a continuously pumped analyzer has been demonstrated for spin echo small angle neutron scattering (SESANS) (Parnell et al , 2015). Compact NSFs with low loss AFP NMR for on-beam operation have been developed at KEK 23 (Ino et al , 2012, 2005).…”
Section: Neutron Spin-filtersmentioning
confidence: 99%
“…The SESAME beamline 33 provides a pulsed, polarized neutron beam with wavelengths in the range from 2 to 10 Å and polarization up to 92%. The neutrons are polarized using a supermirror bender 32 and the polarization is analysed using a continuously pumped 3 He filter.…”
Section: Device Calibrationmentioning
confidence: 99%