2017
DOI: 10.1016/j.apsusc.2016.11.229
|View full text |Cite
|
Sign up to set email alerts
|

Spot size and pulse number dependence of femtosecond laser ablation thresholds of silicon and stainless steel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
34
0
2

Year Published

2017
2017
2021
2021

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 75 publications
(38 citation statements)
references
References 37 publications
2
34
0
2
Order By: Relevance
“…The mistake would be to optimise pulse energy to find the highest ablation efficiency and optimum fluence than use maximum average power from the laser to reach the highest ablation rate by increasing the spot size to maintain the optimum fluence. When the beam size on the sample surface is increased, the ablation threshold F th is decreased due to the possibility for laser radiation to hit a defect 20,21 , meaning that the optimum fluence F opt may shift down. According to the ablation model, the optimal and threshold fluences are interrelated 6 :…”
Section: Resultsmentioning
confidence: 99%
“…The mistake would be to optimise pulse energy to find the highest ablation efficiency and optimum fluence than use maximum average power from the laser to reach the highest ablation rate by increasing the spot size to maintain the optimum fluence. When the beam size on the sample surface is increased, the ablation threshold F th is decreased due to the possibility for laser radiation to hit a defect 20,21 , meaning that the optimum fluence F opt may shift down. According to the ablation model, the optimal and threshold fluences are interrelated 6 :…”
Section: Resultsmentioning
confidence: 99%
“…Sixty discs (10 mm diameter x1.2 mm thickness) were cut from cylinders which were milled from zirconia blanks; these dimensions were chosen In order to standardize the dimension with biaxial flexural test according to ISO:6872 (26) . Sintering of the specimens was done according to the manufacturers recommendation at high temperature furnace at 1450ᵒC according to ISO 13356:2015 (27) , to generate dense structures, as dense material prevent penetration of the water Phase Transformation, Surface Topography and Mechanical Properties of Hydrothermal Aged (223) to bulk of the material.. However, increasing the sintering temperature above 1550ᵒC, lead to formation of large grain, pores and surface cracks and water penetertation, hence,be more susceptable to LTD (28) .…”
Section: Discussionmentioning
confidence: 99%
“…The majority of reports describe ablation characteristics measured at fixed spot size, very limited number of studies investigating the dependence of the ablation properties on spot size can be found [20,21,22]. The study proving the phenomenon of spot size dependence of ablation characteristics for fused silica was carried out only in a limited range of beam radii of less than 10 µm [23].…”
Section: Discussionmentioning
confidence: 99%