2019
DOI: 10.3389/fbuil.2019.00047
|View full text |Cite
|
Sign up to set email alerts
|

Stop Criteria for Flexure for Proof Load Testing of Reinforced Concrete Structures

Abstract: Existing bridges with large uncertainties can be assessed with a proof load test. In a proof load test, a load representative of the factored live load is applied to the bridge at the critical position. If the bridge can carry this load without distress, the proof load test shows experimentally that the bridge fulfills the requirements of the code. Because large loads are applied during proof load tests, the structure or element that is tested needs to be carefully monitored during the test. The monitored stru… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 21 publications
0
11
0
Order By: Relevance
“…In proof-loadings, a load safety factor will be applied and it can therefore be argued that a larger crack width may be acceptable. Hence, it can also be argued that the values described by [30] (w max ≤ 0.11-0.19 mm) might be overly conservative. This open discussion seems to present an opportunity for "crack detection" to be a more governing criterion and perhaps that is the way to proceed.…”
Section: Evaluation Of Results Towards Proof-loadingmentioning
confidence: 99%
See 4 more Smart Citations
“…In proof-loadings, a load safety factor will be applied and it can therefore be argued that a larger crack width may be acceptable. Hence, it can also be argued that the values described by [30] (w max ≤ 0.11-0.19 mm) might be overly conservative. This open discussion seems to present an opportunity for "crack detection" to be a more governing criterion and perhaps that is the way to proceed.…”
Section: Evaluation Of Results Towards Proof-loadingmentioning
confidence: 99%
“…Of the mentioned guidelines, the German guidelines offer stop criteria for crack widths in buildings, w max ≤ 0.5 mm for new cracks and w max ≤ 0.3 mm for existing cracks. A more recent theoretically based criteria is proposed by [30]. In the presented research, the calculated values for crack widths vary from w max ≤ 0.11 mm to w max ≤ 0.19 mm.…”
Section: Monitoring and Stop Criteriamentioning
confidence: 97%
See 3 more Smart Citations