2011
DOI: 10.1016/j.tsf.2011.02.016
|View full text |Cite
|
Sign up to set email alerts
|

Strain in electroless copper films monitored by X-ray diffraction during and after deposition and its dependence on bath chemistry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
11
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 13 publications
4
11
0
Order By: Relevance
“…The change in stress state after baking or long sit times is due to the metastable nature of the deposited Cu grains, which tend to coarsen into larger grains with time to eliminate grain boundaries and reduce overall interfacial energy of the system. This phenomenon of a compressive deposit relaxing to a tensile state has been reported previously for electroless and electroplated Cu films [2,3]. For a given plating current density, the electrolytic Cu plating solution impacted the magnitude and evolution of stress in the plated deposit.…”
Section: Cu Deposit Stress Resultssupporting
confidence: 76%
“…The change in stress state after baking or long sit times is due to the metastable nature of the deposited Cu grains, which tend to coarsen into larger grains with time to eliminate grain boundaries and reduce overall interfacial energy of the system. This phenomenon of a compressive deposit relaxing to a tensile state has been reported previously for electroless and electroplated Cu films [2,3]. For a given plating current density, the electrolytic Cu plating solution impacted the magnitude and evolution of stress in the plated deposit.…”
Section: Cu Deposit Stress Resultssupporting
confidence: 76%
“…We have observed this relaxation previously in nickel-free electroless Cu films, whereas in films with small amounts of co-plated nickel this relaxation process is partially or fully suppressed [5,8]. Clearly, although Ni has been co-deposited, in the present films the Cu atoms in the GBs have retained some of their mobility.…”
Section: Time Evolution Of Average Film Stresssupporting
confidence: 48%
“…c o m / l o c a t e / m e e q ! and the direction normal to the film [5]. The sample was tilted by ψ about the χ-axis, located in the scattering plane and perpendicular to the scattering vector.…”
Section: Contents Lists Available At Sciencedirectmentioning
confidence: 99%
See 1 more Smart Citation
“…The strain evolution of films was determined based on three types of electrolyte. Within the experimental ambiguity, the correlation among stress and strain for the Cu films approves with the properties of bulk polycrystalline Cu [61]. The coating of Cu on particles of B 4 C is required in order to synthesize metal-ceramic composites with improved sinterability and dispersability.…”
Section: Nanocharacteristics Of Electroless Coppermentioning
confidence: 95%