2016
DOI: 10.1093/chromsci/bmw149
|View full text |Cite
|
Sign up to set email alerts
|

Studies on Behaviors of Interactions Between New Polymer-based ZIC-HILIC Stationary Phases and Carboxylic Acids

Abstract: Zwitterionic stationary phases with nearly identical capacities were prepared by graft polymerization of a series of sulfobetaine precursors onto the surface of porous PS/DVB particles. The different spacer lengths are used as an investigative tool for the retention behavior of carboxylic acids; namely malonic, succinic, glutaric and maleic acid. In zwitterionic ion chromatography-hydrophilic interaction liquid chromatography (ZIC-HILIC) separation mode, the retention characteristic of carboxylic acids was exa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 31 publications
(14 citation statements)
references
References 25 publications
0
14
0
Order By: Relevance
“…The stationary phases used for the separation of SBS were performed onto the PS/DVB, using PEEK columns (100 × 4 mm ID) by means of grafted sulfobetaine monomers. [13][14][15][16] HPLC grade of ACN was purchased from Aldrich (total 99.93 percent). The capacity of the ZIC1 and ZIC5 columns are 432 and 488 μeq g -1 , 10 respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The stationary phases used for the separation of SBS were performed onto the PS/DVB, using PEEK columns (100 × 4 mm ID) by means of grafted sulfobetaine monomers. [13][14][15][16] HPLC grade of ACN was purchased from Aldrich (total 99.93 percent). The capacity of the ZIC1 and ZIC5 columns are 432 and 488 μeq g -1 , 10 respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, the linearization of the stationary phase functional groups, while ACN is present, is improved. 14 The pharmaceutical retention decreased or increased with an increasing buffer concentration in stationary ZIC-HILIC phases. The explanation for this is the exchange of cations and anions.…”
Section: Eluent Concentration Effect On Sbs Retentionmentioning
confidence: 99%
“…ZIC1 and ZIC5 were developed on the polystyrene-divinylbenzene (PS/DVB), by means of a grafted sulfobetaine monomer (100 × 4 mm ID) and PEEK column, for the 2-deoxycytidine separation. 5,[9][10][11] The systematic cycle of grafting reaction has been established by Raskop et al 20 Chemicals 2-deoxycytidine (HPLC) purchased by Sigma-Aldrich 99%. Acetic acid was purchased from BDH.…”
Section: Instrumentation and Chromatographic Conditionmentioning
confidence: 99%
“…Hydrophilic and polar compounds, as compared to hydrophobic neutral compounds, are retained preferentially in HILIC the contrary of RP-HPLC. Thus recently, HILIC technology has thus recently begun to increase dramatically in the estimation of drugs, nucleosides, carboxylic acids, inorganic ions, and amino acids by Rasheed and its co-workers [24][25][26][27][28][29][30][31][32][33][34]. Experimental…”
Section: Introductionmentioning
confidence: 99%