Submillisievert CT angiography for carotid arteries using wide array CT scanner and latest iterative reconstruction algorithm in comparison with previous generations technologies: Feasibility and diagnostic accuracy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 18 publications
1
10
0
Order By: Relevance
“…The obtained data sets of each CTA were transferred to a dedicated imageprocessing workstation (Advantage Workstation Version 4.6, GE Healthcare, Milwaukee, WI). CTA images were evaluated by two experienced readers, blinded to the scan protocol, in terms of image quality and presence of artifacts (17). Plaque type was classified according to density measurements based on previously reported criteria (18).…”
Section: Ct Angiography Evaluationmentioning
confidence: 99%
“…The obtained data sets of each CTA were transferred to a dedicated imageprocessing workstation (Advantage Workstation Version 4.6, GE Healthcare, Milwaukee, WI). CTA images were evaluated by two experienced readers, blinded to the scan protocol, in terms of image quality and presence of artifacts (17). Plaque type was classified according to density measurements based on previously reported criteria (18).…”
Section: Ct Angiography Evaluationmentioning
confidence: 99%
“…The use of lower kV values would, on one hand, improve the attenuation of the opacified lumen but conversely slightly reduce the visualization of periluminal tissues on the other hand. Nevertheless, when no plaque component measurements are required (e.g., follow-up examinations), and depending on the clinical context, lower kV settings and application of modern noise reduction mechanisms (e.g., iterative reconstruction techniques) can be successfully applied, delivering good diagnostic performance at lower radiation exposure levels [129][130][131].…”
Section: Technical Parametersmentioning
confidence: 99%
“…reconstruction algorithm make it possible to achieve a marked patient dose reduction. In particular, Annoni et al demonstrated the combined use of 80 KVp, 160 mm detector coverage and iterative reconstruction algorithm in CTA of carotid artery lead to an overall mean effective dose reduction up to 86 % compared to the previous generation 64-slice CT scanner using standard 100 kVp tube voltage and first-generation adaptive statistical iterative reconstruction algorithm [14]…”
Section: Role Of Cta Scansmentioning
confidence: 99%
“…There is tremendous interest today in the application of artificial intelligence (AI) in diagnostic imaging and in the entire discipline of medicine [13]. AI is potentially able to support radiologists and clinicians in their days to days routine in different tasks, including optimization of image reconstruction [14] and reduction in time analysis [15,16].…”
Section: Introductionmentioning
confidence: 99%