1985
DOI: 10.1136/bjsm.19.4.197
|View full text |Cite
|
Sign up to set email alerts
|

Sweat collection from athletes.

Abstract: The difficulty in taking sweat during heavy physical exercise has drawn the authors into testing a technique of sampling generally used in paediatrics. The fact that the results, which have been dealt with statistically, should coincide with the physiological facts already published allows us to consider a use of the technique in order to investigate the physiological mechanisms in action during sweating under different metabolic conditions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

1990
1990
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…Local sweat analysis has been investigated using gauze pads or highly absorbent pads (Figure b) . Sweat rate is calculated from pre/post‐exercise pad weights and the sweat compound analysis is performed via centrifugation.…”
Section: Sweat Collectorsmentioning
confidence: 99%
“…Local sweat analysis has been investigated using gauze pads or highly absorbent pads (Figure b) . Sweat rate is calculated from pre/post‐exercise pad weights and the sweat compound analysis is performed via centrifugation.…”
Section: Sweat Collectorsmentioning
confidence: 99%
“…Once the testing has completed, the solution is drained through the brass liquid solenoid valves (Adafruit-product ID #996, New York City, NY, USA) to the bottom trash bin. The custom-made metal controller box (Diarco model [16][17][18][19][20][21][22][23][24] hand press brake was used) was used to place all of the electronic components where a metal frame was slid into the box.…”
Section: Methodsmentioning
confidence: 99%
“…With the real-time sweat monitoring devices on the rise, sweat collection methods become more crucial. Traditional methods, such as whole body wash [18] or absorbent pads [19] cannot be used for these portable devices, where only microliters of sweat are necessary. Therefore, significant efforts were spent on first modifying the traditional sweat collection methods to fit into a smaller form-factor for portability, such as Macroduct [16,20] (a commercial sweat collection device that was developed for Cystic Fibrosis diagnosis on infants [21]), fabric wicking [6], and modified absorbent pads [22].…”
Section: Introductionmentioning
confidence: 99%
“…Changes in lactate sweat levels reflect the fitness level and correspond to the exercise intensity. 34,35 Sweat lactate can also be used as a marker of tissue viability and may provide warning for pressure ischemia, reflecting the insufficient oxidative metabolism and a compromised tissue viability. 36 …”
Section: Introductionmentioning
confidence: 99%