2022
DOI: 10.3390/metabo12020165
|View full text |Cite
|
Sign up to set email alerts
|

Systematic Evaluation of HILIC Stationary Phases for Global Metabolomics of Human Plasma

Abstract: Polar hydrophilic metabolites have been identified as important actors in many biochemical pathways. Despite continuous improvement and refinement of hydrophilic interaction liquid chromatography (HILIC) platforms, its application in global polar metabolomics has been underutilized. In this study, we aimed to systematically evaluate polar stationary phases for untargeted metabolomics by using HILIC columns (neutral and zwitterionic) that have been exploited widely in targeted approaches. To do so, high-resolut… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
16
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
3

Relationship

3
6

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 32 publications
3
16
0
Order By: Relevance
“…The innovation of this method is the isolation of LDL via two-step sequential precipitation: (1) by heparin, which removes most contaminating serum proteins ( 32 ); (2) by Mg 2+ , combined with an intermediate step of LDL solubilization in 4% NaCl which eliminates any remnant serum proteins ( 32 , 33 ). These steps neutralize matrix effects mostly through ion suppression ( 34 , 35 ). The protocol steps are as follows:…”
Section: Methodsmentioning
confidence: 99%
“…The innovation of this method is the isolation of LDL via two-step sequential precipitation: (1) by heparin, which removes most contaminating serum proteins ( 32 ); (2) by Mg 2+ , combined with an intermediate step of LDL solubilization in 4% NaCl which eliminates any remnant serum proteins ( 32 , 33 ). These steps neutralize matrix effects mostly through ion suppression ( 34 , 35 ). The protocol steps are as follows:…”
Section: Methodsmentioning
confidence: 99%
“…Despite the precision of our experiment, a limited number of samples could be the reason but for the rest of the study, this consequence was not a bias. Concerning “biologically meaningless noise level” for − ESI HILIC analysis, this phenomenon was totally independent from extraction because this method is known to the high noise level [ 24 , 25 ].…”
Section: Discussionmentioning
confidence: 99%
“…Chromatographic separation was performed using the SeQuant ZIC-c HILIC HPLC column (2.1 mm × 100 mm, 3.0 ÎŒm, Merck, Darmstadt, Germany) on a Shimadzu Nexera Ultra high-performance liquid chromatograph (LC) (Duisburg, Germany). The LC method was adapted from a previously described method . Mobile phase A consists of 90% acetonitrile and 10% water with 5 mM ammonium formate, and mobile phase B consists of 10% acetonitrile and 90% water with 5 mM ammonium formate.…”
Section: Methodsmentioning
confidence: 99%
“…The LC method was adapted from a previously described method. 35 Mobile phase A consists of 90% acetonitrile and 10% water with 5 mM ammonium formate, and mobile phase B consists of 10% acetonitrile and 90% water with 5 mM ammonium formate. The injection volume was 3 ÎŒL.…”
Section: Methodsmentioning
confidence: 99%