2018
DOI: 10.1016/j.jmbbm.2018.05.042
|View full text |Cite
|
Sign up to set email alerts
|

Tensile biomechanical properties and constitutive parameters of human corneal stroma extracted by SMILE procedure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 26 publications
0
20
0
Order By: Relevance
“…For the purposes of the current study, the experimentally derived stress-versus-strain data were fit to the above material model. The parameters μ 1 and α 1 are hyperelastic constants obtained from fitting the experimental stress-versus-strain data, with the values of 0.60415Mpa and 16.54, respectively [15]. The Poisson ratio values of the human cornea ranges from 0.42 to 0.5, which denotes that the cornea tissue exhibits a nearly incompressible behavior [16].…”
Section: Materials Propertiesmentioning
confidence: 99%
“…For the purposes of the current study, the experimentally derived stress-versus-strain data were fit to the above material model. The parameters μ 1 and α 1 are hyperelastic constants obtained from fitting the experimental stress-versus-strain data, with the values of 0.60415Mpa and 16.54, respectively [15]. The Poisson ratio values of the human cornea ranges from 0.42 to 0.5, which denotes that the cornea tissue exhibits a nearly incompressible behavior [16].…”
Section: Materials Propertiesmentioning
confidence: 99%
“…While the material parameters of the corneal stromal lenticules have be measured through uniaxial tensile test in the previous study [ 12 ], the purpose of this study was to investigate the mechanical anisotropy of the normal human corneal stroma using stromal lenticules extracted during SMILE as part of an effort to elucidate the biomechanical behavior of the human cornea.…”
Section: Introductionmentioning
confidence: 99%
“… 30 Similar results have also been reported. 31 Considering that uniaxial tensile test cannot measure the anisotropy of a specific sample, it can only measure the difference of the mean value of the horizontal and vertical mechanical properties of large samples. The difference between previous studies and our results may be caused by the moderate myopic corneal stromal lenticules they used.…”
Section: Discussionmentioning
confidence: 99%