2018
DOI: 10.1016/j.nima.2018.07.001
|View full text |Cite
|
Sign up to set email alerts
|

The beamline ID32 at the ESRF for soft X-ray high energy resolution resonant inelastic X-ray scattering and polarisation dependent X-ray absorption spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
87
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 109 publications
(88 citation statements)
references
References 35 publications
0
87
0
Order By: Relevance
“…The sample growth and characterization methods have been reported previously [35][36][37]. The RIXS measurements were performed with the ERIXS spectrometer at the beam line ID32 of the European Synchrotron Radiation Facility (ESRF) in Grenoble, France [38]. The RIXS spectra were collected at 20K with π incident polarization (parallel to the scattering plane) to maximize the single-magnon signal [2,39].…”
Section: Methodsmentioning
confidence: 99%
“…The sample growth and characterization methods have been reported previously [35][36][37]. The RIXS measurements were performed with the ERIXS spectrometer at the beam line ID32 of the European Synchrotron Radiation Facility (ESRF) in Grenoble, France [38]. The RIXS spectra were collected at 20K with π incident polarization (parallel to the scattering plane) to maximize the single-magnon signal [2,39].…”
Section: Methodsmentioning
confidence: 99%
“…To date, XFEL-based RIXS tends to lag behind synchrotron experiments in terms of energy and momentum resolution. Many of the technical developments implemented at synchrotrons [17,56] can potentially be employed at XFELs provided further practical complications, such as limited experimental floor space, compatibility with other experiments, finite beam stability, can be avoided or overcome. In many cases shorter spectrometers ( 2 m compared to ∼ 15 m at synchrotrons) are more practical at XFELs.…”
Section: (A) New Xfels and Rixs Spectrometersmentioning
confidence: 99%
“…For a systematic and quantitative study of the different ordering phenomena in RNiO 3 , high-quality RIXS spectra with high-resolution are necessary. We therefore performed the RIXS experiments at the ID32 beamline of the European Synchrotron Radiation Facility using the ERIXS spectrometer 45 . As a compromise between reasonable acquisition time and sufficient resolving power, the combined instrumental energy resolution was set to ≈ 50 meV full width at half maximum (FWHM).…”
Section: A Experimental Detailsmentioning
confidence: 99%