2013
DOI: 10.1016/j.compositesb.2012.05.052
|View full text |Cite
|
Sign up to set email alerts
|

The effects of manufacturing-induced and in-service related bonding quality reduction on the mode-I fracture toughness of composite bonded joints for aeronautical use

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
95
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 144 publications
(97 citation statements)
references
References 22 publications
1
95
0
1
Order By: Relevance
“…In the case of improper curing of the adhesive, it was shown that the lowered temperature have great impact on the bond performance. The GIC for sample cured at 120⁰C drops nearly by 95% in relation to GIC for sample properly cured at 180⁰C [2]. As far as the de-icing fluid is considered it was shown that it has a negative effect on both mode I and mode II fracture toughness of the bonded joints.…”
Section: Introductionmentioning
confidence: 97%
“…In the case of improper curing of the adhesive, it was shown that the lowered temperature have great impact on the bond performance. The GIC for sample cured at 120⁰C drops nearly by 95% in relation to GIC for sample properly cured at 180⁰C [2]. As far as the de-icing fluid is considered it was shown that it has a negative effect on both mode I and mode II fracture toughness of the bonded joints.…”
Section: Introductionmentioning
confidence: 97%
“…CFRP panels undergo several pre-treatment procedures, such as wet abrasion and the water brake test to ensure the effectiveness of the cleaning procedure [16,17]. Although precaution measures are implemented, such as large autoclaves to remove moisture by heat-drying, the problem persists.…”
Section: Pre-bond Contamination Of Cfrpsmentioning
confidence: 99%
“…Si-contamination on the CFRP surface caused by release agent residuals hinders the adhesion of the adhesive onto the substrate [16,17].…”
Section: Pre-bond Contamination Of Cfrpsmentioning
confidence: 99%
See 1 more Smart Citation
“…[2] Research shows that the fracture surface of DCB test coupons show adhesive failure when defects such as pre-bond contamination, pre-bond moisture and uncured adhesive are present at the bond line. [3,4,5] As a consequence, fracture toughness values under opening mode (G IC ) significantly decrease, which is a direct result from the crack growing at the interface instead of inside the adhesive layer (cohesive failure-good adhesion quality). [6,7] The same studies also show that neither ultrasonic C-scan nor X-ray tomography are able to detect those defects prior to testing.…”
Section: Introductionmentioning
confidence: 99%