2002
DOI: 10.1088/0957-0233/13/6/310
|View full text |Cite
|
Sign up to set email alerts
|

The error analysis and online measurement of linear slide motion error in machine tools

Abstract: A new accurate two-probe time domain method is put forward to measure the straight-going component motion error in machine tools. The characteristics of non-periodic and non-closing in the straightness profile error are liable to bring about higher-order harmonic component distortion in the measurement results. However, this distortion can be avoided by the new accurate two-probe time domain method through the symmetry continuation algorithm, uniformity and least squares method. The harmonic suppression… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…In 1986, Tanaka and Sato analyzed the STP method extensively and developed the sequentialthree-points (STRP) which can measure both straightness and yawing error of the slide [16]. With more than two probes, some EST has been applied to avoid the scanning error from the probe and shorten the sampling interval to obtain better results [17][18][19][20][21]. Under the mature use of EST, the straightness of the slide is measured on a flat plane with little profile variation.…”
Section: Improved Error Separation Technique For On-machine Optical L...mentioning
confidence: 99%
See 1 more Smart Citation
“…In 1986, Tanaka and Sato analyzed the STP method extensively and developed the sequentialthree-points (STRP) which can measure both straightness and yawing error of the slide [16]. With more than two probes, some EST has been applied to avoid the scanning error from the probe and shorten the sampling interval to obtain better results [17][18][19][20][21]. Under the mature use of EST, the straightness of the slide is measured on a flat plane with little profile variation.…”
Section: Improved Error Separation Technique For On-machine Optical L...mentioning
confidence: 99%
“…3. Traditional EST demands a sampling interval which is equal to the distance of two probes, approximately [13][14][15][16][17][18][19][20][21].…”
Section: Improved Error Separation Technique For On-machine Optical L...mentioning
confidence: 99%
“…2) External Interference. In external electromagnetic radiation interference, micro-vibration and other factors, the sensor output voltage signal is burr-like [4], and the duration of action was short. while after removing the source of interference the converted A/D value will tend to smooth.…”
Section: Error Analysismentioning
confidence: 99%
“…Su et al [6] proposed a two-probe time domain method. Gao et al [7] describes a scanning multi-probe system for measuring straightness profiles of cylinder workpieces.…”
Section: Introductionmentioning
confidence: 99%