2004
DOI: 10.1111/j.1365-2966.2004.08259.x
|View full text |Cite
|
Sign up to set email alerts
|

The European Large AreaISOSurvey - VIII. 90-μm final analysis and source counts

Abstract: We present a re-analysis of the European Large Area Infrared Space Observatory (ISO) Survey (ELAIS) 90-µm observations carried out with ISOPHOT, an instrument on board the ISO of the European Space Agency. With more than 12 deg 2 , the ELAIS survey is the largest area covered by ISO in a single programme and is about one order of magnitude deeper than the IRAS 100-µm survey. The data analysis is presented and was mainly performed with the PHOT interactive analysis software but using the pairwise method of Stic… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
30
0

Year Published

2005
2005
2014
2014

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(33 citation statements)
references
References 53 publications
2
30
0
Order By: Relevance
“…Figure 12 illustrates both 850-870µm number counts (from Scuba, Laboca, Scuba-2, and ALMA Blain et al, 1999;Scott et al, 2002;Chapman et al, 2002;Cowie et al, 2002;Borys et al, 2003;Webb et al, 2003;Barnard et al, 2004;Coppin et al, 2006;Scott et al, 2006;Knudsen et al, 2008;Beelen et al, 2008;Weiß et al, 2009a;Karim et al, 2013;Casey et al, 2013;Chen et al, 2013a) and 450-500µm (from Scuba, Herschel and Scuba-2 Smail et al, 2002;Oliver et al, 2010;Clements et al, 2010;Béthermin et al, 2012b;Geach et al, 2013;Casey et al, 2013;Chen et al, 2013a). Figure 13 illustrates other infrared and submillimeter number counts in the literature in direct units, from 70µm Béthermin et al, 2010a;Berta et al, 2011), 100µm (Héraudeau et al, 2004;Rodighiero & Franceschini, 2004;Kawara et al, 2004;Berta et al, 2011;Magnelli et al, 2013b), 160µm Kawara et al, 2004;Béthermin et al, 2010a;Berta et al, 2011;Magnelli et al, 2013b), 250µm and 350µm Chen+13 (850) Casey+13 (850 Figure 12: Differential submillimeter number counts at 850µm/870µm (left) and 450-500 µm (right). The 850µm and 870µm number counts come the initial Scuba surveys …”
Section: Number Countsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 12 illustrates both 850-870µm number counts (from Scuba, Laboca, Scuba-2, and ALMA Blain et al, 1999;Scott et al, 2002;Chapman et al, 2002;Cowie et al, 2002;Borys et al, 2003;Webb et al, 2003;Barnard et al, 2004;Coppin et al, 2006;Scott et al, 2006;Knudsen et al, 2008;Beelen et al, 2008;Weiß et al, 2009a;Karim et al, 2013;Casey et al, 2013;Chen et al, 2013a) and 450-500µm (from Scuba, Herschel and Scuba-2 Smail et al, 2002;Oliver et al, 2010;Clements et al, 2010;Béthermin et al, 2012b;Geach et al, 2013;Casey et al, 2013;Chen et al, 2013a). Figure 13 illustrates other infrared and submillimeter number counts in the literature in direct units, from 70µm Béthermin et al, 2010a;Berta et al, 2011), 100µm (Héraudeau et al, 2004;Rodighiero & Franceschini, 2004;Kawara et al, 2004;Berta et al, 2011;Magnelli et al, 2013b), 160µm Kawara et al, 2004;Béthermin et al, 2010a;Berta et al, 2011;Magnelli et al, 2013b), 250µm and 350µm Chen+13 (850) Casey+13 (850 Figure 12: Differential submillimeter number counts at 850µm/870µm (left) and 450-500 µm (right). The 850µm and 870µm number counts come the initial Scuba surveys …”
Section: Number Countsmentioning
confidence: 99%
“…The 70µm data is collated from Spitzer MIPS Béthermin et al, 2010a) and Herschel PACS . At 100µm, data are from the ISOPHOT instrument aboard ISO (Héraudeau et al, 2004;Rodighiero & Franceschini, 2004;Kawara et al, 2004) and Herschel PACS Magnelli et al, 2013b). At 160µm-170µm, data are from Spitzer MIPS Béthermin et al, 2010a), ISO ISOPHOT (Kawara et al, 2004), and Herschel PACS Magnelli et al, 2013b).…”
Section: Parametrizing Number Countsmentioning
confidence: 99%
“…Shaded areas represent ISO and Spitzer data (Rodighiero & Franceschini 2004;Héraudeau et al 2004;Béthermin et al 2010). Inset: Collection of PACS number counts, including this work (red, limited to relative errors ≤15% for clarity sake), PEP Abell 2218 (grey, Altieri et al 2010) and HerMES-PACS (light-blue, Aussel et al, in prep.).…”
Section: Number Countsmentioning
confidence: 99%
“…Counts have been obtained down to 95 mJy (Héraudeau et al 2004) resolving less than 5% of the CIB as derived from DIRBE by Renault et al (2001).…”
Section: The Status Of Deep Surveys: Resolvedmentioning
confidence: 99%