1986
DOI: 10.1016/0309-1740(86)90033-1
|View full text |Cite
|
Sign up to set email alerts
|

The use of filter paper to estimate drip loss of porcine musculature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
141
3

Year Published

1999
1999
2015
2015

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 261 publications
(145 citation statements)
references
References 5 publications
1
141
3
Order By: Relevance
“…Instrumental color measurements were recorded for L* (lightness; 0: black, 100: white), a* (redness/ greenness; positive values: red, negative values: green) and b* (yellowness/blueness; positive values: yellow, negative values: blue) using a Minolta Chroma Meter, CR-301 (Konica Minolta, Tokyo, Japan). The drip losses of the loin samples were determined using the procedure of Kauffman et al (1986). Duplicate loin samples were trimmed to 3 cm × 3 cm × 3 cm size and blotted to remove the surface water, and the initial loin weight was determined.…”
Section: Methodsmentioning
confidence: 99%
“…Instrumental color measurements were recorded for L* (lightness; 0: black, 100: white), a* (redness/ greenness; positive values: red, negative values: green) and b* (yellowness/blueness; positive values: yellow, negative values: blue) using a Minolta Chroma Meter, CR-301 (Konica Minolta, Tokyo, Japan). The drip losses of the loin samples were determined using the procedure of Kauffman et al (1986). Duplicate loin samples were trimmed to 3 cm × 3 cm × 3 cm size and blotted to remove the surface water, and the initial loin weight was determined.…”
Section: Methodsmentioning
confidence: 99%
“…The following measurements were conducted on all muscles after 0 days' storage; colour of the muscle surface after 30 min bloom at 4 C, ultimate pH, surface exudate 10 min after exposing the surface (Kauffman et al 1986), Warner-Bratzler peak shear force and cooking loss. Also at 0 days of storage, samples were removed for sarcoplasmic protein solubility, sarcomere length and myofibrillar ATPase activity.…”
Section: Sample Collection and Meat Quality Determinationmentioning
confidence: 99%
“…The lightness (L*), redness (a*), and yellowness (b*) color values were measured using color difference meter (Yasuda Seiko Co., CR-310, Minolta, Tokyo, Japan) at day 0, and days 5 and 10 of vacuum storage by using the standard method of CIE. Drip loss was determined by the method of Kauffman et al (1986) and lipid peroxidation was measured by TBARS assay as per the method of Sinnhuber and Yu (1977).…”
Section: Carcass Characteristics and Pork Quality Evaluationmentioning
confidence: 99%