“…the rate determining step is the diffusion of ferrocyanide from the cells to the electrode surface). [16][17][18][19][20]24 ݅ ௦௦ = ‫ݎܥܦܨ݊4‬…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…the rate determining step is the diffusion of ferrocyanide from the cells to the electrode surface). [16][17][18][19][20]24 ݅ ௦௦ = ‫ݎܥܦܨ݊4‬…”
Section: Resultsmentioning
confidence: 99%
“…6,[16][17][18][19][20] It is therefore possible to determine the total [Fe(CN) 6 ] 4concentration in solution at a given time, but not to measure fast enzyme kinetics. [Fe(CN) 6 ] 3mediated BOD tests and toxicity tests are carried out by measuring the total [Fe(CN) 6 ] 4concentration after a defined incubation time 16,[18][19][20]. The steady state diffusion limited current for [Fe(CN) 6 ] 4oxidation is measured at a planar disc microelectrode and the concentration of [Fe(CN) 6 ] 4in solution is calculated using equation 5, where n is the number of electrons in the electron transfer step, F is Faraday's constant, C is the concentration of ferrocyanide, D is the diffusion coefficient of [Fe(CN) 6 ] 4and r is the radius of the electrode.…”
mentioning
confidence: 99%
“…Extracting accurate kinetic information therefore requires a measurement in a reaction free sample, e.g. after centrifugation to remove the biocatalyst 4 5 7 8 12 21 .…”
mentioning
confidence: 99%
“…The BOD of the inflow sample (Table 2), however, was underestimated and this has been observed previously for primary effluent using this rapid method (Catterall et al, 2003); it is probably due to the higher complexity and concentration of polymers and recalcitrant compounds present in the sample (Liu and Mattiasson, 2002). Previous studies Catterall et al, 2001) showed that single microorganisms tend to underestimate the biodegradation of amino acids and overestimate that of simple sugars, and questioned the validity of the GGA solution as a calibration standard for MICREDOX ® .…”
Section: Response Of Immobilised Cells To Wastewater Samplesmentioning