Three-dimensional computational fluid dynamics modeling of particle uptake by an occupational air sampler using manually-scaled and adaptive grids

Abstract: This work presents fluid flow and particle trajectory simulation studies to determine the aspiration efficiency of a horizontally oriented occupational air sampler using computational fluid dynamics (CFD). Grid adaption and manual scaling of the grids were applied to two sampler prototypes based on a 37-mm cassette. The standard k–ε model was used to simulate the turbulent air flow and a second order streamline-upwind discretization scheme was used to stabilize convective terms of the Navier–Stokes equations. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…The Bland-Altman also reveals that while there are a few metal samples outside of the 95% confidence intervals, or two standard deviations of the mean, a majority of the samples are clustered near a mean difference of zero, meaning that the prototype and IOM concentrations actually matched each other quite well, especially when metal concentrations were lower. This adds to study evidence supporting the prototype's applicability for sampling lower concentrations Koehler & Peters, 2015;L'Orange et al, 2016;Landazuri et al, 2016;Stewart et al, 2017).…”
Section: Discussionmentioning
confidence: 79%
See 2 more Smart Citations
“…The Bland-Altman also reveals that while there are a few metal samples outside of the 95% confidence intervals, or two standard deviations of the mean, a majority of the samples are clustered near a mean difference of zero, meaning that the prototype and IOM concentrations actually matched each other quite well, especially when metal concentrations were lower. This adds to study evidence supporting the prototype's applicability for sampling lower concentrations Koehler & Peters, 2015;L'Orange et al, 2016;Landazuri et al, 2016;Stewart et al, 2017).…”
Section: Discussionmentioning
confidence: 79%
“…Due to the higher flow rate of this sampler at 10 L min -1 , several studies indicate that the prototype sampler yields promise for detecting lower concentrations and potentially for shortening necessary sampling durations L'Orange et al, 2016;Landazuri et al, 2016;Stewart et al, 2017). The 3-piece prototype performance closely matches the inhalable sampling criterion and is therefore deemed a simpler alternative to both the Button and IOM samplers L'Orange et al, 2016).…”
Section: A5 -Not Suspected As a Human Carcinogenmentioning
confidence: 98%
See 1 more Smart Citation