Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
67
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 103 publications
(67 citation statements)
references
References 8 publications
0
67
0
Order By: Relevance
“…Three sets of experiments were performed to study the possible influence by different choices of the reference volume. In the first set, the ground-truth volume at the averaged state was used; in the second set, the reference volume was reconstructed from the simulated projections of the pulsating phantom, using the FBP algorithm [19]; and in the third set, the reference volume was obtained the same way as the second set, but the phantom was not pulsating. We denote these three sets as GT, FBP1, and FBP2, respectively, for the simplification of explanation.…”
Section: ) Effects Of Reference Volume Selectionmentioning
confidence: 99%
See 1 more Smart Citation
“…Three sets of experiments were performed to study the possible influence by different choices of the reference volume. In the first set, the ground-truth volume at the averaged state was used; in the second set, the reference volume was reconstructed from the simulated projections of the pulsating phantom, using the FBP algorithm [19]; and in the third set, the reference volume was obtained the same way as the second set, but the phantom was not pulsating. We denote these three sets as GT, FBP1, and FBP2, respectively, for the simplification of explanation.…”
Section: ) Effects Of Reference Volume Selectionmentioning
confidence: 99%
“…Schäfer et al [17] reconstructed moving coronary arteries by shifting voxel positions according to a motion vector field. This method is only applicable to voxel driven cone-beam filtered back-projection (FBP) reconstruction approaches [18], [19] with an a priori known motion model. To perform gated reconstruction, the authors introduced a weighting factor into the FBP formulation according to the cardiac phase of the projections.…”
Section: Introductionmentioning
confidence: 99%
“…The calibration is performed by taking x-ray images from a known dodecahedron phantom from a large number of projections, equally distributed over the hemisphere of possible C-arm locations. 24,25 For any position in-between the calibrated positions, the deviations are linearly averaged from the neighboring calibrated data.…”
Section: -D-3-d Registrationmentioning
confidence: 99%
“…The basic idea to acquire projection data over a typically 180°-plus fan angle was already pursued in the 1990s [1][2][3][4]. The early work was conducted on C-arm systems equipped with conventional image intensifiers (Fig.…”
Section: Introductionmentioning
confidence: 99%