2020
DOI: 10.1016/j.nima.2020.163592
|View full text |Cite
|
Sign up to set email alerts
|

Timing performance of a Micro-Channel-Plate Photomultiplier Tube

Abstract: The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r<5.5 mm) the time resolution of the two MCP-PMTs combined is better than 10 ps. The signal amplitude decreases in the outer region due to less light reachin… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 12 publications
1
14
0
Order By: Relevance
“…A radial non-uniformity (up to about 60 ps) of the MCP-PMT time response was observed as a function of the distance of the MIP impact point from the centre of the MCP-PMT. A similar effect has also been reported in other studies [6]. This non-uniformity was studied in dedicated runs in which the relative position of the MCP-PMT and of a single crystal bar was varied.…”
Section: Micro Channel Plate Photomultiplier As Time Referencesupporting
confidence: 76%
“…A radial non-uniformity (up to about 60 ps) of the MCP-PMT time response was observed as a function of the distance of the MIP impact point from the centre of the MCP-PMT. A similar effect has also been reported in other studies [6]. This non-uniformity was studied in dedicated runs in which the relative position of the MCP-PMT and of a single crystal bar was varied.…”
Section: Micro Channel Plate Photomultiplier As Time Referencesupporting
confidence: 76%
“…Despite comparatively low detection efficiencies (10-40% typical in the visible region [51]), the timing jitter can be extremely low, e.g. <10 ps in the study by Bortfeldt et al [52], and PMTs are still widely used in a range of applications [53,54]. SPADs are based on semiconductor pn junctions reverse biased above the breakdown voltage.…”
mentioning
confidence: 99%
“…We expect the development of head-mounted 2P miniscopes to continue during the years to come. While the MINI2P microscope has now been miniaturized sufficiently for use in a broad range of behavioral tasks that afford unrestrained behavior, miniature optics such as metalenses will lead to further decreases in weight and size of the microscope (Arbabi et al, 2018), and miniaturized photodetectors will allow in-situ signal detection so that the connection cable can be yet more flexible (Bortfeldt et al, 2020). Moreover, while the current miniscope enables recording from more than a thousand neurons at a time, pulse-multiplexing technology (Cheng et al, 2011) and adaptive optics (Ji, 2017; Wang et al, 2014) will undoubtedly increase the cell yield further.…”
Section: Discussionmentioning