Torsional properties of twisted and machined endodontic files

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
27
0
4

Year Published

2008
2008
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 40 publications
(35 citation statements)
references
References 9 publications
4
27
0
4
Order By: Relevance
“…The two parameters evaluated were angular deflection at failure and maximum torque, and the methods used have been widely used (6,7). The results showed that the Mtwo retreatment file #15 exhibited greater angular deflection at failure when compared with the other instruments tested.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The two parameters evaluated were angular deflection at failure and maximum torque, and the methods used have been widely used (6,7). The results showed that the Mtwo retreatment file #15 exhibited greater angular deflection at failure when compared with the other instruments tested.…”
Section: Discussionmentioning
confidence: 99%
“…The torsional assay was performed as described elsewhere (6,7). Torsion without axial load was applied with a device attached to the crosshead of the universal testing machine.…”
Section: Methodsmentioning
confidence: 99%
“…Of particular interest was the observation of the dimpling that appeared when pressure was focused on the center of the shaft (19). The only study to date that also uses a retreatment file is that of Lopes et al (13) (9)(10)(11)(12). However, the fracture surfaces observed in the present study were fracture surfaces of files after undergoing torsional resistance tests, and were not the area of tip immobilization after torsional fracture tests.…”
Section: Methodsmentioning
confidence: 60%
“…According to these reports, the rotary Ni-Ti file can remove gutta-percha from the root canal more quickly than hand implements. There have been many reports of various torsional resistance tests performed on Ni-Ti files in use (9)(10)(11)(12)(13)(14)(15). In addition, various designs of gutta-percha removal Ni-Ti files have been documented.…”
Section: Introductionmentioning
confidence: 99%
“…De acordo com Matheus et al (5) ao realizarem ensaios mecânicos em instrumentos endodônticos estabeleceu-se uma relação média de aumento do ângulo de torção máximo com o aumento do diâmetro nominal dos instrumentos de duas marcas comerciais. Todavia, para Campos e Pertot, (6) ,Canalda-Sahli, BrauAguadé e Berastegui-Jimeno (7) e Seto, Nicholls e Harrington, (8) o ângulo de torção máximo na fratura, para instrumentos manuais de NiTi, diminui com o aumento do diâmetro nominal do instrumento endodôntico, enquanto que, Carmo et al (9) afirmam que o ângulo de rotação não é influenciado pelo aumento do diâmetro do instrumento.…”
Section: Introductionunclassified