2016
DOI: 10.1109/tpwrs.2016.2523265
|View full text |Cite
|
Sign up to set email alerts
|

Toward Simulation-Free Estimation of Critical Clearing Time

Abstract: Abstract-Contingency screening for transient stability of large scale, strongly nonlinear, interconnected power systems is one of the most computationally challenging parts of Dynamic Security Assessment and requires huge resources to perform time-domain simulations-based assessment. To reduce computational cost of time-domain simulations, direct energy methods have been extensively developed. However, these methods, as well as other existing methods, still rely on time-consuming numerical integration of the f… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 32 publications
(19 citation statements)
references
References 27 publications
0
19
0
Order By: Relevance
“…Theorem 1: Consider a given initial state δ 0 inside the set P. Assume that the EP of the system takes different values in the set A(δ 0 ) = Λ ∩ B(δ 0 ), where the set B(δ 0 ) is defined as in (9). Then, the system state always converges from the given initial state δ 0 to the EP.…”
Section: A Stability Assessment By Using Energy Functionmentioning
confidence: 99%
See 1 more Smart Citation
“…Theorem 1: Consider a given initial state δ 0 inside the set P. Assume that the EP of the system takes different values in the set A(δ 0 ) = Λ ∩ B(δ 0 ), where the set B(δ 0 ) is defined as in (9). Then, the system state always converges from the given initial state δ 0 to the EP.…”
Section: A Stability Assessment By Using Energy Functionmentioning
confidence: 99%
“…Here a kj = V k V j B kj , where B kj is the (normalized) susceptance of the transmission line {k, j} connecting the k th bus and j th bus. N k is the set of neighboring buses of the k th bus (see [9] for more details). Let δ(t) = [δ 1 (t) ... δ |N | (t)δ 1 (t) ...δ |N | (t)] be the state of the system (1) at time t (for simplicity, we will denote the system state by δ).…”
Section: Inverse Stability Problem Of Power Systemsmentioning
confidence: 99%
“…For definiteness we could now choose the sign of w(α) so that S(x, α 0 ) > 0 for unstable trajectories and S(x, α 0 ) < 0 for stable trajectories. However, any consistent sign for w(α) and S can be used, since the sensitivity formula (13) does not depend on the sign of S.…”
Section: B Defining the Function S That Describes W Smentioning
confidence: 99%
“…To compute the sensitivity of the critical clearing time with respect to load impedances α Z and generator inertias α H as parameters, we use MATLAB to evaluate all the steps in Section V and hence evaluate formula (13). All the numerical integrations use the MATLAB ode15s solver.…”
Section: Sensitivity Computationsmentioning
confidence: 99%
See 1 more Smart Citation