2014
DOI: 10.1088/1752-7155/8/2/026003
|View full text |Cite
|
Sign up to set email alerts
|

Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors

Abstract: Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath. The aim of this study was to determine that mid-infrared (MIR; 3-20 µm) gas phase sensing is capable of determining isoprene in exhaled breath as an exemplary medically relevant VOC by hyphenati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
33
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 44 publications
(33 citation statements)
references
References 36 publications
0
33
0
Order By: Relevance
“…These can be considered as volatile biomarkers within the exhaled breath matrix. The most concentrated endogenous constituents in breath are isoprene (12–580 ppb), ethanol (13–1000 ppb), methanol (160–2000 ppb), and acetone (1.2–1800 ppb); other alcohols are present in the very low ppb concentration range [ 24 ].…”
Section: Interfering Expired Gases and Its Effectsmentioning
confidence: 99%
“…These can be considered as volatile biomarkers within the exhaled breath matrix. The most concentrated endogenous constituents in breath are isoprene (12–580 ppb), ethanol (13–1000 ppb), methanol (160–2000 ppb), and acetone (1.2–1800 ppb); other alcohols are present in the very low ppb concentration range [ 24 ].…”
Section: Interfering Expired Gases and Its Effectsmentioning
confidence: 99%
“…18 iHWGs provide unmatched compactness and exibility for gas sensing with a footprint of only 75 Â 50 Â 12 mm (L Â W Â H). While such devices have been efficiently coupled to spectrometers operating in the mid-infrared region for the detection of e.g., 12 CO 2 / 13 CO 2 , 19 ozone, 20 hydrogen sulphide, 21 and isoprene, 22 iHWGs have not been coupled to a near-infrared sensor system yet.…”
Section: Introductionmentioning
confidence: 99%
“…A c c e p t e d M a n u s c r i p t mechanical stability[14,[17][18][19][20][21][22][23][24][25][26]. Radiation from the IR spectrometer is focused into the iHWG, and propagated onto the internal DTGS detector of the ALPHA via two gold-coated off-axis parabolic mirrors (OAPM; diam: 1") with an effective focal length of 2" (Janos Technology Inc, Keene/NH, USA).…”
mentioning
confidence: 99%