2011
DOI: 10.1002/elan.201100317
|View full text |Cite
|
Sign up to set email alerts
|

Trace Levels Determination of Ammonium by Flow Injection Analysis Using Gas‐Diffusion and Capacitively Coupled Contactless Conductivity Detection

Abstract: A sensitive analytical method based on gas-diffusion flow injection system for ammonium ion determination at trace levels with capacitively coupled contactless conductivity detection (C 4 D) is described. The effects of the chemical composition of the acceptor stream, operating frequency of the conductivity detector, acceptor and donor flow rates, injected volume, and some potential interferents were evaluated. By injecting 100 mL samples, the analytical method showed linear response for ammonium from 2.0 up t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 30 publications
0
10
0
Order By: Relevance
“…Applications of C 4 D without electrophoretic or chromatographic separation include flow injection analysis (FIA) , SI analysis , and other methods operating with liquid or even gaseous flows. FIA was also used in the testing of C 4 D on a microfluidic device using simple salt solutions at different concentrations .…”
Section: C4d In Other Flow‐through Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Applications of C 4 D without electrophoretic or chromatographic separation include flow injection analysis (FIA) , SI analysis , and other methods operating with liquid or even gaseous flows. FIA was also used in the testing of C 4 D on a microfluidic device using simple salt solutions at different concentrations .…”
Section: C4d In Other Flow‐through Methodsmentioning
confidence: 99%
“…Ammonium in the sample was volatilized when transported through the gas diffusion cell and trapped into an acidic acceptor solution on the other side of the cell. The acceptor solution was then directly delivered to the C 4 D for sensitive NH 4 + determination . A schematic of this system is shown in Fig.…”
Section: C4d In Other Flow‐through Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Conductometry, normally a nonselective technique, has been used with a FI-GDU system for measuring Kjeldahl Nitrogen in milk and chicken digests [5]. Contactless conductometry works particularly well with small bore tubing; this has also been used for NH þ 4 determination with a FI-GDU system [6]. Other automated flow methods, e.g., sequential injection [7], multi syringe FI [8,9], and multi-commutation FI [10,11] have all been used with a GDU and spectrophotometric NH þ 4 determination.…”
Section: Introductionmentioning
confidence: 99%
“…Determination of ammonium by flow injection analysis with gaseous diffusion (FIA-GD) and spectrophotometric detection allows avoid matrix problems, therefore it became very popular among different FIA methods [6,7]. However, many other flow systems for determination of ammonium with different kinds of detection [8][9][10][11][12] or flow systems coupled with other methods are also presented in literature [13,14]. FIA-GD is a technique based on injection of a liquid sample volume into a moving non-segmented carrier stream.…”
Section: Introductionmentioning
confidence: 99%