Abstract: In our institution, an individualized dosimetric quality assurance protocol for intensity modulated radiotherapy (IMRT) is being implemented. This protocol includes dosimetric measurements with a fluoroscopic electronic portal imaging device (EPID) for all IMRT fields while the patient is being irradiated. For some of the first patients enrolled in this protocol, significant beam attenuation by (carbon fiber) components of the treatment couch was observed. To study this beam attenuation in two-dimensional, EPI… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
39
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(39 citation statements)
references
References 25 publications
0
39
0
Order By: Relevance
“…Second, the dose delivered to the patient's skin due to the loss of the skin-sparing effect in the buildup region may lead to clinically important skin reactions. Although the attenuation and loss of buildup caused by the carbon fi ber tabletop has already been demonstrated by several groups, [12][13][14][15] there are few studies with respect to its effects on the surface dose. On the other hand, these studies have not refl ected the data concerning all types of tabletop.…”
Section: Introductionmentioning
confidence: 97%
“…Second, the dose delivered to the patient's skin due to the loss of the skin-sparing effect in the buildup region may lead to clinically important skin reactions. Although the attenuation and loss of buildup caused by the carbon fi ber tabletop has already been demonstrated by several groups, [12][13][14][15] there are few studies with respect to its effects on the surface dose. On the other hand, these studies have not refl ected the data concerning all types of tabletop.…”
Section: Introductionmentioning
confidence: 97%
“…4 When the couch is between the radiation source and the patient, the dose distribution is altered by both attenuation and the loss of the skin sparing in the dose buildup region. [5][6][7] This work examines these two effects for two different solid top carbon fiber couches as well as the ability of a commercial treatment planning system ͑CMS XiO version 4.33.02͒ to model these perturbations. It is important to document the magnitude of these dose effects and how well they are modeled by a modern TPS, as this information is required to determine if the clinical problem warrants resource allocation.…”
Section: Introductionmentioning
confidence: 99%
“…However, attention must be paid when irradiating through the couch with oblique gantry angles. In their study on head-and-neck cancer irradiation with a 6-MV photon beam, Vieira et al [19] measured 15% beam attenuation for a posterior oblique beam. Yorke [23] and Muthuswamy & Lam [14] calculated a range of forbidden gantry angles for specific patient setups.…”
Section: Introductionmentioning
confidence: 99%