2015
DOI: 10.1016/j.snb.2015.06.009
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive electrochemical cancer cells sensor based on trimetallic dendritic Au@PtPd nanoparticles for signal amplification on lab-on-paper device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 64 publications
(27 citation statements)
references
References 44 publications
0
27
0
Order By: Relevance
“…Mean pore diameter distribution of the materials were 9.9, 11.9, and 6.09 for KCC-1, KCC-1-NH 2 , and KCC-1-NH 2 -Cys, respectively (Supporting information Figure S4 (see supporting information)). The pore size, pore volumes, and surface area of KCC-1, KCC-1-NH 2 , and KCC-1-NH 2 -Cys are obviously approved by the reported results [27,29]. Zeta potentials of KCC-1, KCC-1-NH 2 , and KCC-1-NH 2 -Cys were checked at pH 7.5 to determine the surface charge to identify the possible surface modification.…”
Section: Synthesismentioning
confidence: 83%
“…Mean pore diameter distribution of the materials were 9.9, 11.9, and 6.09 for KCC-1, KCC-1-NH 2 , and KCC-1-NH 2 -Cys, respectively (Supporting information Figure S4 (see supporting information)). The pore size, pore volumes, and surface area of KCC-1, KCC-1-NH 2 , and KCC-1-NH 2 -Cys are obviously approved by the reported results [27,29]. Zeta potentials of KCC-1, KCC-1-NH 2 , and KCC-1-NH 2 -Cys were checked at pH 7.5 to determine the surface charge to identify the possible surface modification.…”
Section: Synthesismentioning
confidence: 83%
“…Yu and co‐workers developed a paper microfluidics for detection of cancer cells based on electrochemistry . Au@PdPt nanoparticles with peroxidase‐like catalytic activity were conjugated with folic acid which could bind to K562 cells and the Au‐paper electrode was used as working electrode.…”
Section: Cell Capture/phenotyping On Paper Microfluidic Devicesmentioning
confidence: 99%
“…Folic acid–folate receptor‐based cancer cell capture and detection. Reproduced with permission . Copyright 2015, Elsevier Ltd. B) The schematic diagram of fabrication and operation procedure for the paper‐based electro‐chemiluminescence cyto‐device.…”
Section: Cell Capture/phenotyping On Paper Microfluidic Devicesmentioning
confidence: 99%
“…The same authors developed another K-562 cells biosensor on a related origami paper-based platform [39]. The cells were captured by folic acid-functionalized AuNPs grown on the surface of the cellulose fibers, in the paper sample zone of the SPCE.…”
Section: Paper-based Electrochemical Biosensorsmentioning
confidence: 99%
“…Additionally, the stability of the catalytic nanoprobes was improved in comparison with redox enzyme based assays (e.g., horseradish peroxidase, HRP). The sensor also demonstrated good precision and reproducibility with relative standard deviations of intra-assays and inter-assays lower than 5% [39]. …”
Section: Paper-based Electrochemical Biosensorsmentioning
confidence: 99%