2018
DOI: 10.1016/j.bios.2018.07.025
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive label-free electrochemical immunosensor based on PVA-co-PE nanofibrous membrane for the detection of chloramphenicol residues in milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 85 publications
(28 citation statements)
references
References 47 publications
0
28
0
Order By: Relevance
“…PVA-co-PE nanofibrous membrane was fabricated according to the literature [16,17]. PVA-co-PE (Mn = 90,000) was added into a mixture of isopropanol and water (weight ratio 7:3) with stirring at 80°C for 2 h to prepare electrospinning solutions.…”
Section: Fabrication Of Pva-co-pe Nanofibrous Membranesmentioning
confidence: 99%
“…PVA-co-PE nanofibrous membrane was fabricated according to the literature [16,17]. PVA-co-PE (Mn = 90,000) was added into a mixture of isopropanol and water (weight ratio 7:3) with stirring at 80°C for 2 h to prepare electrospinning solutions.…”
Section: Fabrication Of Pva-co-pe Nanofibrous Membranesmentioning
confidence: 99%
“…Electrochemical immunosensors have enhanced sensitivity and offer a highly improved selectivity due to the specific antibody-antigen molecular recognition reaction. Thus, CAP detection using immunosensors was based either on the increase of the current generated by CAP reduction [ 104 ] or by the decrease of the signal of a redox probe, e.g., K 3 [Fe(CN) 6 ], [ 103 ] with increased concentrations of CAP that was bound to the CAP-antibody immobilized at the electrode surface. Aptasensors are electrodes modified with aptamers that are single stranded oligonucleotides with characteristic identification sites and configuration that enable a specific interaction with the analyte, thus enabling the selective accumulation of the target species.…”
Section: Principles Of Amphenicol Electrochemical Detectionmentioning
confidence: 99%
“…Another free-labeled immunosensor for chloramphenicol quantification was based on a screen-printed carbon electrode laminated with a layer of poly (vinyl alcohol- co -ethylene) (PVA- co -PE) nanofibrous membrane, that was covalently immobilized with an anti-chloramphenicol antibody [91]. The amperometrically monitored current of reduction of nitro groups of the captured antibiotic molecules on the antibody-modified screen-printed electrodes was an analytical signal.…”
Section: Recent Reports On Electrochemical Immunosensors Designatementioning
confidence: 99%