New Trends and Developments in Metrology 2016
DOI: 10.5772/62437
|View full text |Cite
|
Sign up to set email alerts
|

Uncertainty of Measurement in Medical Laboratories

Abstract: The Guide to the Expression of Uncertainty in Measurement GUM is not systematically used in medical laboratories, for what the laboratorian should understand the Uncertainty "pproach and its importance to recognize the level of realism of results. This chapter presents, discusses, and recommends the models fulfilling GUM principles. "n example is given to a single test for an easier understanding of the determination of measurement uncertainty. "ll the practice uses a freeware. Results with larger measurement … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 24 publications
0
5
0
2
Order By: Relevance
“…This document examines the practical experience in assessing the uncertainty of measurement in chemical laboratories, and emphasizes the need to integrate procedures that assess the uncertainty of measurement with measurements of existing quality control carried out in laboratories. In this way, the validation of the method in the MU assessment was clearly enabled, and in full compliance with the GUM document, which enabled the empirical approach or the top-down model of the MU assessment in the routine medical laboratories (9).…”
Section: Models For Calculating the Measurement Uncertainty Of The Rementioning
confidence: 95%
See 1 more Smart Citation
“…This document examines the practical experience in assessing the uncertainty of measurement in chemical laboratories, and emphasizes the need to integrate procedures that assess the uncertainty of measurement with measurements of existing quality control carried out in laboratories. In this way, the validation of the method in the MU assessment was clearly enabled, and in full compliance with the GUM document, which enabled the empirical approach or the top-down model of the MU assessment in the routine medical laboratories (9).…”
Section: Models For Calculating the Measurement Uncertainty Of The Rementioning
confidence: 95%
“…factors leading to the final MU, i.e. has a very large budget of uncertainty (a list of factors leading to MU) (9). It is necessary to define a large number of variations and covariances and use complex mathematical modeling, so it is not suitable for use in routine laboratory medicine.…”
Section: Models For Calculating the Measurement Uncertainty Of The Rementioning
confidence: 99%
“…Компоненты неопределенности на аналитическом этапе: -ошибки калибровки; -случайные и систематические ошибки из-за деградации реагента или плохого обслуживания прибора и аналитической вариабельности; -эффекты окружающей среды на аналитические процессы (например, высокая температура в помещении или прямой солнечный свет); -субъективные ошибки, включая ошибки манипуляции с образцами; -инструментальная погрешность в точке принятия решения; -ошибки приписанных значений калибраторов; -аппроксимации, включенные в измерения [3].…”
Section: значение неопределенности измерений (ни) в практике клинико-unclassified
“…Расчет является результатом применения статистических методов, учитывающих все эти компоненты. Как правило, такие расчеты недоступны для медицинских лабораторий и используются в референсных лабораториях для моделирования неопределенности внедряемой методики [3,6].…”
Section: описание референсного метода оценки ниunclassified
“…[6]). The determination of measurement uncertainty is demonstrated uniquely in ordinal diagnostic tests [25,26]. In such cases, this terminology could be adapted to "measurement uncertainty of binary results."…”
Section: General Conceptmentioning
confidence: 99%