1984
DOI: 10.1093/ajcp/81.5.634
|View full text |Cite
|
Sign up to set email alerts
|

Urine Screening Strategy Employing Dipstick Analysis and Selective Culture: An Evaluation

Abstract: A cost-effective urinalysis test strategy, employing screening dipstick analysis with sediment microscopy performed on urines positive for leukocyte esterase, nitrite, protein, or blood, is evaluated. Screening urine culture is done when greater than or equal to 5 WBC/HPF, greater than 10 bacteria/HPF, or yeasts are found on sediment microscopy. Predictive value, sensitivity, and specificity of the test strategy in predicting significant bacteriuria is compared with sediment microscopy, Gram staining of uncent… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

1985
1985
1990
1990

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(11 citation statements)
references
References 0 publications
0
11
0
Order By: Relevance
“…The initial problem of specimens clogging the filter has been solved by increasing the vacuum force which causes the entire specimen to be pulled through the filter card. The Bac-T-Screen is a sensitive screening test (98%) for detecting clinically significant bacteriuria (49). When compared with the clinical classification of infection rather than quantitative urine cultures, the sensitivity of the Bac-T-Screen was higher than that of the culture method at 2105 CFU/ml, 98 and 45%, respectively.…”
Section: Colorimetric Filtrationmentioning
confidence: 99%
See 3 more Smart Citations
“…The initial problem of specimens clogging the filter has been solved by increasing the vacuum force which causes the entire specimen to be pulled through the filter card. The Bac-T-Screen is a sensitive screening test (98%) for detecting clinically significant bacteriuria (49). When compared with the clinical classification of infection rather than quantitative urine cultures, the sensitivity of the Bac-T-Screen was higher than that of the culture method at 2105 CFU/ml, 98 and 45%, respectively.…”
Section: Colorimetric Filtrationmentioning
confidence: 99%
“…Loo and associates used the Chemstrip-9 (Bio-Dynamics) to determine the urine specimen workup (49). If (69).…”
Section: Laboratory Approach To Screeningmentioning
confidence: 99%
See 2 more Smart Citations
“…In others, special care was taken, such s the use of sterilized Containers and collection of clean voided, midstream or catheter urine (5,7,12,13,14,22).…”
Section: Discussionmentioning
confidence: 99%