2006
DOI: 10.1016/s1120-1797(06)80004-9
|View full text |Cite
|
Sign up to set email alerts
|

Use of GAFCHROMIC XR type R films for skin-dose measurements in interventional radiology: Validation of a dosimetric procedure on a sample of patients undergone interventional cardiology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
12
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(13 citation statements)
references
References 25 publications
1
12
0
Order By: Relevance
“…Radiochromic films have been studied [62] and successfully employed to measure dose within diagnostic energy range during diagnostic CT scans [63], CBCT acquisitions [64], and interventional radiology procedures [65]. Figure 7h represents dose profiles measured with XR-QA GAFCHROMICä film strips laced between humanoid Rando phantom sections within pelvic region during CBCT image acquisition, commonly employed n he course of Image Guided Radiotherapy (IGRT).…”
Section: Radiochromic Film Applicationsmentioning
confidence: 99%
“…Radiochromic films have been studied [62] and successfully employed to measure dose within diagnostic energy range during diagnostic CT scans [63], CBCT acquisitions [64], and interventional radiology procedures [65]. Figure 7h represents dose profiles measured with XR-QA GAFCHROMICä film strips laced between humanoid Rando phantom sections within pelvic region during CBCT image acquisition, commonly employed n he course of Image Guided Radiotherapy (IGRT).…”
Section: Radiochromic Film Applicationsmentioning
confidence: 99%
“…In recent years, ISP has provided the medical physics community with a series of film type dosimeters which have found niche uses in therapeutic and diagnostic radiology. Historically these have included MD-55 and HS film [6][7][8][9][10][11][12] , ISP's films designed specifically for radiotherapy applications where large doses (up to 30 Gy) are required, XR-R films [13][14][15] for high dose diagnostic imaging applications through to films such as XRQA [16][17] which is designed for low dose assessment at kilovoltage x-ray energies. Probably the most used film for radiation dosimetry in therapy applications has been Gafchromic EBT film [18][19][20][21][22][23][24] .…”
Section: Introductionmentioning
confidence: 99%
“…Bordier et al (5) claims that the accuracy in indicated maximum ESAK is within 25% verified with phantom measurements. A suitable method to estimate ESAK is to use Gafchromic film placed in direct contact with the patient's body during the interventional procedure, sampling all exposures (6,7,8) . However, this method is complicated and time consuming and cannot be used on a regular basis.…”
Section: Introductionmentioning
confidence: 99%