1992
DOI: 10.1002/mcs.1220040402
|View full text |Cite
|
Sign up to set email alerts
|

Use of SFC/MS for the confirmation of peak identities in the SFC/FID chromatogram of olestra

Abstract: Abstract. Open tubular supercritical fluid chromatography (SFC) with flame ionization detection (FID) has been used for characterizing olestra, a mixture of fatty acid sucrose esters. In this publication, we describe SFC/mass spectrometry (SFC/MS) of olestra using the direct fluid introduction interface. Chemical ionization spectra were used in confirming SFC/FID peak identities. Electron ionization SFC/MS of olestra was also investigated. Both major and minor component peaks in the SFC chromatogram of olestra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

1993
1993
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…Cryopumping was shown to enhance signal by a factor of 5 in some cases. Cryopumping was later used to assist in the identification of high molecular weight components of olestra, a mixture of fatty acid sucrose esters (123). Buecherl et al built and tested an interface, incorporating a second restriction and a stage of pumping between the SFC restrictor and the ion source, for coupling open-tubular SFC to highresolution MS (124).…”
Section: Sfc Instrumentation Techniques and Performancementioning
confidence: 99%
See 1 more Smart Citation
“…Cryopumping was shown to enhance signal by a factor of 5 in some cases. Cryopumping was later used to assist in the identification of high molecular weight components of olestra, a mixture of fatty acid sucrose esters (123). Buecherl et al built and tested an interface, incorporating a second restriction and a stage of pumping between the SFC restrictor and the ion source, for coupling open-tubular SFC to highresolution MS (124).…”
Section: Sfc Instrumentation Techniques and Performancementioning
confidence: 99%
“…Combining two 50-µm-i.d., 10-m-long columns enhanced the separation of one critical pair by 23%. The SFC/MS characterization of olestra, a noncaloric fat replacement, was described by Pinkston and Bowling (123). Both CI and EI spectra of major and minor components were obtained using a modified direct fluid introduction interface.…”
Section: Sfc Instrumentation Techniques and Performancementioning
confidence: 99%