Validation of in vivo 2D Displacements from Spiral Cine DENSE at 3T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
1

Year Published

2016
2016
2018
2018

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(10 citation statements)
references
References 0 publications
0
9
1
Order By: Relevance
“…We observed that myocardial strain measured using DENSE was higher at 1.5T compared with 3.0T. Looking 24 and Wehner et al 25 did not observe any differences in strain between field strengths; however, the sample size in both studies was small. The 3.0T scanner used in this study had a 70 cm bore, while the 1.5T had a 60 cm bore.…”
Section: Discussioncontrasting
confidence: 49%
“…We observed that myocardial strain measured using DENSE was higher at 1.5T compared with 3.0T. Looking 24 and Wehner et al 25 did not observe any differences in strain between field strengths; however, the sample size in both studies was small. The 3.0T scanner used in this study had a 70 cm bore, while the 1.5T had a 60 cm bore.…”
Section: Discussioncontrasting
confidence: 49%
“…All volunteer imaging was performed on 3T systems (Magnetom Trio and Magnetom Prisma, Siemens Healthcare) with a phased‐array body coil (6‐channel for Magnetom Trio and 18‐channel for Magnetom Prisma) and a 32‐channel spine coil. After the acquisition of localizer images, a mid‐ventricular short‐axis slice was acquired during both breath‐holding and free‐breathing acquisitions with the following parameters: FOV = 160 × 160 mm 2 , thickness of localized stimulated echo = 80–100 mm 2 , 6 spiral interleaves per image, 2 interleaves per heartbeat, spiral readout length of 3.4 ms, in‐plane spatial resolution of 3 × 3 mm 2 , slice thickness = 8 mm, TR = 15 ms, TE = 1.08 ms, and temporal resolution of 30 ms. Ramped flip angles with a final flip angle of 15 ° were used to achieve a consistent SNR through the cardiac cycle . Fat suppression was used by applying a fat saturation pulse immediately after ECG triggering as previously described .…”
Section: Methodsmentioning
confidence: 99%
“…The apparent SNR was measured from magnitude‐reconstructed images using a region of interest (ROI) that included all of the myocardium within a slice and a large background ROI. The apparent SNR was calculated as the mean of the myocardial ROI divided by the standard deviation of the background ROI, and the correction for the Rician distribution of the magnitude signal was applied . In addition, phase quality (the variance of the local 2D spatial derivative of the phase image) was measured from all of the manually segmented myocardium within each slice.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Here, we focus on methods applied to full-field measures, 5 where either strains or displacements due to known applied loads are measured on the surface or the boundaries of the domain of interest and also in its interior. For example, using magnetic resonance imaging (MRI), the heart's displacement field due to the filling pressure can be measured at many hundreds of homogeneously spaced locations (eg, 2 × 2 mm in plane resolution) inside the myocardial wall (see, eg, studies [6][7][8].…”
Section: Introductionmentioning
confidence: 99%