Voltammetric behaviour and quantitative determination of pesticide iminoctadine

Abstract: Iminoctadine (IOD) was determined in spiked river water samples by square wave voltammetry (SWV) using a cyclic renewable silver amalgam film electrode (Hg(Ag)FE). It was found that the compound can act as an electrocatalyst. In Britton-Robinson buffer at pH 6.5 a signal connected with the catalytic hydrogen evolution reaction was detected at À1.8 V versus Ag/AgCl. Validation of the method was carried out. The LOD and LOQ have been estimated to be 2.6 Â 10 À9 mol L À1 and 8.5 Â 10 À9 mol L À1 , respectively.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 34 publications
0
12
0
Order By: Relevance
“…A plethora of intriguing studies has been conducted in relation to the kinetics of charge transfer processes at liquid/liquid interfaces [18][19][20][21][22][23], electrochemistry of immobilized proteins [24,25], and catalytic mechanisms [26][27][28], revealing that SWV is highly suited for both mechanistic and kinetic characterization of electrode reactions, besides its excellent analytical performances [29][30][31][32][33][34] and its appropriateness for bioanalytical applications [35][36][37][38][39][40][41].…”
Section: Introductionmentioning
confidence: 99%
“…A plethora of intriguing studies has been conducted in relation to the kinetics of charge transfer processes at liquid/liquid interfaces [18][19][20][21][22][23], electrochemistry of immobilized proteins [24,25], and catalytic mechanisms [26][27][28], revealing that SWV is highly suited for both mechanistic and kinetic characterization of electrode reactions, besides its excellent analytical performances [29][30][31][32][33][34] and its appropriateness for bioanalytical applications [35][36][37][38][39][40][41].…”
Section: Introductionmentioning
confidence: 99%
“…As can be seen in Table 2, in order to obtain satisfying results it is necessary to control the pH of the supporting electrolyte with very high precision. The signals recorded using amalgam film electrodes originated from the reduction of the nitro [74][75][76][77][78], keto [79], azo [80], chinone [81], pyrimidine [72], pteridine [72], adenine [82] groups or hydrogen evolution catalyzed by organic compounds adsorbed at the surface of the electrode [73,[83][84][85][86]. Although the reduction of the above-listed organic compounds occurs in more than one step, in most cases only one peak was considered useful for analytical purposes.…”
Section: Organic Analysismentioning
confidence: 99%
“…More direct approach using silver amalgam based electrodes is also a recurring theme in the contemporary literature [18][19][20][21][22], all the works use a mercury film modified AgSAE for some reason, which uses small amounts of mercury for film renewal, but the mercury has to be in a toxic water soluble form, the film is much less stable than a meniscus and the electrode needs to be polished much more often, which is time consuming. Some works focus on the determination of herbicides at classical mercury electrodes [23] this method utilizes the excellent reproducibility of a hanging mercury drop electrode (HMDE) to deconvolute the signals of three herbicides to determine them in a mixture.…”