2005
DOI: 10.1007/s10786-005-0029-7
|View full text |Cite
|
Sign up to set email alerts
|

Water as an insulator in pulsed facilities (Review)

Abstract: Transmission lines with distributed parameters are often used as electrical energy storage units and high-voltage (high-current) pulse shapers in electrophysical facilities. To increase the pulse power and reduce the dimensions of the equipment, deionized water, purified from mechanical impurities and gas, is used as an insulator in lines. Water has a high breakdown strength ((BS) ~ 130 kV/cm) at pulses with a duration of ~1 µ s and electrode areas of up to tens of square meters, a large value of the relative … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
6
1

Year Published

2005
2005
2015
2015

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 29 publications
(7 citation statements)
references
References 13 publications
0
6
1
Order By: Relevance
“…The observed 3 Volts water breakdown voltage is low and the 300 nm gap is small compared with previous breakdown experiments [1,2,6,7,8]. Furthermore, the applied DC field is uniform across the gap, which is different from the field distributions in spherical geometries.…”
Section: Discussioncontrasting
confidence: 61%
See 1 more Smart Citation
“…The observed 3 Volts water breakdown voltage is low and the 300 nm gap is small compared with previous breakdown experiments [1,2,6,7,8]. Furthermore, the applied DC field is uniform across the gap, which is different from the field distributions in spherical geometries.…”
Section: Discussioncontrasting
confidence: 61%
“…Due to its high permittivity and high dielectric strength, water is a good dielectric medium for pulsed power systems [1], for which water dielectric properties, including electrical breakdown properties, are of great interest. The study of such properties started more than a century ago, yet there are still ongoing efforts to understand them.…”
Section: Introductionmentioning
confidence: 99%
“…Considering existing theories of discharge initiation in liquids [13][14][15] and our current experiments, there are several factors that contribute to the reasons why the NCDP is different from the streamer coronas previously observed in liquid and specifically why the two initial stages of the negative corona are observed. This study is the first which simultaneously combines 1) short rise-time voltages, 2) nanosecond-duration pulses, 3) high temporal resolution emission spectra, and most importantly 4) nanoscale tips.…”
mentioning
confidence: 59%
“…The target fully absorbs the accelerated electrons. Under these conditions, it is advisable to measure the electron beam characteristics using noncontact instruments that do not alter the bremsstrahlung field being formed [5].…”
mentioning
confidence: 99%